AT49BV010-12JI ATMEL [ATMEL Corporation], AT49BV010-12JI Datasheet
AT49BV010-12JI
Related parts for AT49BV010-12JI
AT49BV010-12JI Summary of contents
Page 1
... CE A13 4 29 I/O7 A14 I/O4 26 VCC GND A16 10 23 I/O2 A15 11 22 I/O1 A12 1-Megabit (128K x 8) Single 2.7-volt ™ Battery-Voltage Flash Memory AT49BV010 AT49HBV010 AT49LV010 AT49HLV010 0677B-A–9/97 1 ...
Page 2
... This dual-line control gives designers flexibility in pre- venting bus contention. ERASURE: Before a byte can be reprogrammed, the 128K bytes memory array (or 120K bytes if the boot block fea- tured is used) must be erased. The erased state of the memory bits is a logical “1”. The entire device can be erased at one time by using a 6-byte software code ...
Page 3
For details, see Operating Modes (for hardware operation) or Software Product Identification. The manufacturer and device code is the same for both modes. DATA POLLING: The AT49(H)BV/(H)LV010 features DATA polling to indicate the end of a program cycle. Dur- ing ...
Page 4
... IN X High Z High Z ( Manufacturer Code ( Device Code A16 = V Manufacturer Code A16 = V Device Code IH IL Min Max 0.6 2.0 0.45 = 3.0V 2.4 AT49BV010- - N/A 2.7V to 3.6V (4) (4) (4) (4) Units ...
Page 5
... ACC after the falling edge of CE without impact Output Test Load AC MEASUREMENT 1.8K LEVEL 1.3K (1) Max 6 12 AT49HBV/ AT49BV/ AT49BV010- HLV010-90 LV010-12 Min Max Min Max Min 90 120 90 120 ...
Page 6
AC Byte Load Characteristics Symbol Parameter Address, OE Set-up Time AS OES t Address Hold Time AH t Chip Select Set-up Time CS t Chip Select Hold Time CH t Write Pulse Width (WE or CE) WP ...
Page 7
Program Cycle Characteristics Symbol Parameter t Byte Programming Time BP t Address Set-up Time AS t Address Hold Time AH t Data Set-up Time DS t Data Hold Time DH t Write Pulse Width WP t Write Pulse Width High ...
Page 8
Data Polling Characteristics Symbol Parameter t Data Hold Time Hold Time OEH Output Delay OE t Write Recovery Time WR Notes: 1. These parameters are characterized and not 100% tested. 2. See t spec ...
Page 9
Software Product (1) Identification Entry LOAD DATA AA TO ADDRESS 5555 LOAD DATA 55 TO ADDRESS 2AAA LOAD DATA 90 TO ADDRESS 5555 ENTER PRODUCT IDENTIFICATION (2)(3)(5) MODE Software Product (1) Identification Exit LOAD DATA ADDRESS 5555 ...
Page 10
... AT49HBV010-70TC 32T AT49HBV010-70JI 32J AT49HBV010-70TI 32T AT49HBV010-90JC 32J AT49HBV010-90TC 32T AT49HBV010-90JI 32J AT49HBV010-90TI 32T AT49BV010-12JC 32J AT49BV010-12TC 32T AT49BV010-12JI 32J AT49BV010-12TI 32T AT49BV010-15JC 32J AT49BV010-15TC 32T AT49BV010-15JI 32J AT49BV010-15TI 32T Package Type Operation Range Commercial ( Industrial (- Commercial ...
Page 11
Ordering Information (Continued) I (mA ACC (ns) Active Standby 55 25 0. 0. 0.05 25 0.05 120 25 0.05 25 0.05 32J 32-Lead, Plastic J-Leaded Chip Carrier Package (PLCC) 32T ...