LT3686 LINER [Linear Technology], LT3686 Datasheet - Page 22

no-image

LT3686

Manufacturer Part Number
LT3686
Description
Manufacturer
LINER [Linear Technology]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LT3686AEDD
Manufacturer:
LT
Quantity:
10 000
Part Number:
LT3686AEMSE
Manufacturer:
LT
Quantity:
10 000
Part Number:
LT3686AEMSE#PBF/AI
Manufacturer:
LT
Quantity:
4 906
Part Number:
LT3686AEMSE#PBF/AI/AH
Manufacturer:
LT
Quantity:
73
Part Number:
LT3686AEMSE#TRPBF
Manufacturer:
LINEAR/凌特
Quantity:
20 000
Part Number:
LT3686AHDD
Manufacturer:
LT
Quantity:
10 000
Part Number:
LT3686AIMSE#PBF
Manufacturer:
LINEAR/凌特
Quantity:
20 000
Part Number:
LT3686EDD
Manufacturer:
LINEAR/凌特
Quantity:
20 000
LT3686
ApplicAtions inForMAtion
Frequency Compensation
The LT3686 uses current mode control to regulate the
output. This simplifies loop compensation. In particular,
the LT3686 does not require the ESR of the output capaci-
tor for stability allowing the use of ceramic capacitors to
achieve low output ripple and small circuit size. Figure 16
shows an equivalent circuit for the LT3686 control loop.
The error amp is a transconductance amplifier with finite
output impedance. The power section, consisting of the
modulator, power switch and inductor, is modeled as a
transconductance amplifier generating an output current
proportional to the voltage at the V
output capacitor integrates this current, and that the capaci-
tor on the V
current, resulting in two poles in the loop. R
zero. With the recommended output capacitor, the loop

C
node (C
C
) integrates the error amplifier output
GND
LT3686
R
160k
C
C
100pF
C
C
V
node. Note that the
C
1V
1M
AMPLIFIER
Figure 16. Model for Loop Response
C
ERROR
+
provides a
g
2A/V
m
g
200µA/V
CURRENT MODE
=
POWER STAGE
m
=
+
800mV
crossover occurs above the R
works well as long as the value of the inductor is not too
high and the loop crossover frequency is much lower than
the switching frequency. With a larger ceramic capacitor
(very low ESR), crossover may be lower and a phase lead
capacitor (CPL) across the feedback divider may improve
the phase margin and transient response. Large electrolytic
capacitors may have an ESR large enough to create an
additional zero, and the phase lead may not be necessary.
If the output capacitor is different than the recommended
capacitor, stability should be checked across all operating
conditions, including load current, input voltage and tem-
perature. The LT1375 data sheet contains a more thorough
discussion of loop compensation and describes how to
test the stability using a transient load.
SW
FB
R1
R2
C
PL
+
ESR
C1
3686 F16
OUT
C
C
C1
C
zero. This simple model
3686fa