LM95234_07 NSC [National Semiconductor], LM95234_07 Datasheet - Page 17

no-image

LM95234_07

Manufacturer Part Number
LM95234_07
Description
Quad Remote Diode and Local Temperature Sensor with SMBus Interface and TruTherm Technology
Manufacturer
NSC [National Semiconductor]
Datasheet
1.12 SERIAL INTERFACE RESET
In the event that the SMBus Master is RESET while the
LM95234 is transmitting on the SMBDAT line, the LM95234
must be returned to a known state in the communication pro-
tocol. This may be done in one of two ways:
(c) Serial Bus Read from a Register with the Internal Command Register preset to desired value.
(a) Serial Bus Write to the internal Command Register followed by a the Data Byte
(d) Serial Bus Write followed by a Repeat Start and Immediate Read
(b) Serial Bus Write to the Internal Command Register
FIGURE 8. SMBus Timing Diagrams
17
1.
When SMBDAT is LOW, the LM95234 SMBus state
machine resets to the SMBus idle state if either SMBDAT
or SMBCLK are held low for more than 35ms (t
Note that according to SMBus specification 2.0 all
devices are to timeout when either the SMBCLK or
SMBDAT lines are held low for 25-35ms. Therefore, to
20106310
20106311
20106312
20106314
www.national.com
TIMEOUT
).

Related parts for LM95234_07