ZLF60 ARCH [Arch Electronics Corp.], ZLF60 Datasheet

no-image

ZLF60

Manufacturer Part Number
ZLF60
Description
LED Power
Manufacturer
ARCH [Arch Electronics Corp.]
Datasheet
KEY FEATURES
ELECTRICAL SPECIFICATIONS
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
All specifications valid at normal input voltage, full load and +25°C after warm-up time unless otherwise stated.
Model No.
Max output wattage ( W )
Output
Protection
Isolation
Environment
Physical
Safety
EMC
Input
ZLF60 SERIES
Open Frame LED Power Supply
With Constant Current & Constant Voltage (C.C+C.V mode)
Universal Input: 100-277 VAC
With P.F.C. Function, PF>0.9
High Efficiency up to 90%
Free Air Convection
Protections: Over Load / Over Voltage / Short Circuit
High Reliability & Double Layered PCB
Ultra Compact Size: 4.0 x 2.0 x 1.12 Inches
3-Years Product Warranty
Voltage
Frequency (Hz)
Power factor
Current (Full load)
Inrush current
Leakage Current
Voltage (V.DC.)
Constant Current Operation Voltage (max)
(CC Mode) (Note3)
Voltage Tolerance
Preset Current (mA) (CC Mode)
Current Adjustment Range (mA)
(CC Mode)
Minimum Load (mA)
Line Regulation (100-277VAC) (typ.)
Load Regulation (Min-Max) (typ.)
Ripple & Noise (max)
Efficiency (at 230VAC.)(typ)
Over current protection
Over voltage protection
Short circuit protection
Input-Output (V.AC)
Input-FG
Output-FG .(V.AC)
Operating temperature
Storage temperature
Temperature coefficient
Humidity
MTBF
Dimension (L x W x H)
Weight
Cooling method
Agency Approvals
EMI
(Conducted & Radiated Emission)
EMS (Noise Immunity)
Harmonic Current
Surge
(V.AC)
(Note2)
ZLF60-13.5S
60W
90-295 VAC
50 / 60 Hz
PF>0.9 at Full load (115 VAC / 230 VAC)
0.8A max. (115 VAC) / 0.4A max. (230 VAC)
50 A max. (Cold Start at 230 VAC)
< 0.7 mA max at 240 VAC
13.5V
11~13.5
VDC
±10%
4200
3570~4200
3570
±4%
±5%
4Vp-p
85%
Auto recovery
Zener diode clamp
Auto recovery
3750V
1880V
500V
-30°C…+70°C (with derating)
-40°C…+85°C
0.02%/°C
95% RH
>583,000 h @ 25°C (MIL-HDBK-217F)
4.0 x 2.0 x 1.12 Inches ( 101.6 x 50.8 x 28.5 mm ) Tolerance ±0.5 mm
Free air convection
UL8750、IEC / EN 61347-2-13、 IEC / EN 61347-1
EN 55015
EN 61547
EN 61000-3-2(at Full Load)、EN 61000-3-3
2KV L-L, 4KV L-E
g
(Pending)
(Pending)
ZLF60-24S
24V
18~ 24
VDC
2400
1700~2500
1700
4.5Vp-p
88%
ZLF60-28S
28V
21~28
VDC
2100
1400~2100
1400
5Vp-p
89%
(Pending)
VER :
ZLF60-42S
42V
33.5~ 42
VDC
1400
1100~1400
1100
5Vp-p
89%
(Pending)
PA_0
update :
60 Watts
ZLF60-54S
54V
38~54
VDC
1050
700~1100
700
5Vp-p
90%
LED Power
2012.03.09
-1-

Related parts for ZLF60

ZLF60 Summary of contents

Page 1

... ZLF60 SERIES KEY FEATURES Open Frame LED Power Supply With Constant Current & Constant Voltage (C.C+C.V mode) Universal Input: 100-277 VAC With P.F.C. Function, PF>0.9 High Efficiency up to 90% Free Air Convection Protections: Over Load / Over Voltage / Short Circuit High Reliability & Double Layered PCB Ultra Compact Size: 4 ...

Page 2

... ZLF60 SERIES Note: 1. Ripple & Noise are measured at 20MHz of bandwidth with 0.1uF & 47uF parallel capacitor. 2. Please check the derating curve for more details. 3. Input Voltage=115 or 230 VAC。This is the suitable operation region for LED related application.but please reconfirm special electrical requirements for some specific ststem design ...

Related keywords