Electrical Characteristics (Continued)
V
T
Note 1: Exceeding the absolute maximum rating may damage the device.
Note 2: The device is not guaranteed to function outside its operating range.
Note 3: The maximum allowable power dissipation at any T
Note 4: Output voltage temperature coefficient is the worst case voltage change divided by the total temperature range.
Note 5: Regulation is measured at constant junction temperature using low duty cycle pulse testing. Parts are tested
Note 6: Dropout voltage is defined as the input to output differential at which the output voltage drops 2% below its
V
ΔV
IN
Symbol
PROTECTION
IN
PSRR
V
=Vout+1V; V
I
OUT
TH(EN)
I
– V
MAX
leak
I
Q
(T
and the regulator will go into thermal shutdown. See “Thermal Consideration” section for details.
for load regulation in the load range from 10mA to 200mA. Changes in output voltage due to heating effects are
covered by the thermal regulation specification.
nominal value measured at 1V differential.
/ΔT
OUT
J(MAX)
– T
EN1
Thermal Protection
Dropout Voltage
Quiescent Current
Threshold Voltage
Shutdown Supply
=V
Ripple Rejection
A
Output Voltage
)/Θ
Coefficient
Current Limit
Temperature
Enable Input
EN2
Parameter
JA
Preliminary and all contents are subject to change without prior notice
=V
Current
. Exceeding the maximum allowable power dissipation will result in excessive die temperature,
IN
; I
© Seaward Electronics Inc., 2007. • www.seawardinc.com • Page 4
OUT
= 10mA, C
(4)
(6)
I
IN
OUT
Voltage Decreasing, Output Turns
Voltage Increasing, Output Turns
= 2.2μF; C
Thermal Protection Temperature
Vin=4.5V,Vp-p=1V,Iout=100mA
Channel 1
Channel 2
= 100mA (Both Channel)
LDO Voltage Regulator
Dual 200mA CMOS
Protection Hysterisys
OUT
On, Logic High
Off, Logic Low
(Preliminary)
Conditions
f = 100 Hz,
Channel 1
Channel 2
Channel 1
Channel 2
= 2.2μF; T
No Load
A
(ambient temperature) is calculated using: P
J
I
I
I
I
OUT
OUT
OUT
OUT
= 25°C; unless otherwise specified
= 100mA
= 200mA
= 100mA
= 200mA
Min
200
200
1.6
--
--
--
--
--
--
--
--
--
--
--
--
--
-0.025
-0.63
Typ
128
256
237
427
180
125
110
30
60
--
--
SE5221
Max
0.4
D(MAX)
--
--
--
--
--
--
--
--
--
--
--
--
--
--
5
=
mV/°C
Unit
mV
mA
dB
μA
°C
uA
V