S-100 MEANWELL [Mean Well Enterprises Co., Ltd.], S-100 Datasheet

no-image

S-100

Manufacturer Part Number
S-100
Description
100W Single Output Switching Power Supply
Manufacturer
MEANWELL [Mean Well Enterprises Co., Ltd.]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
S-100-12
Manufacturer:
MEANWELL
Quantity:
2 000
Part Number:
S-100-24
Manufacturer:
MEANWELL
Quantity:
2 000
Part Number:
S-100-5
Manufacturer:
MV
Quantity:
20 000
Part Number:
S-10001A
Manufacturer:
FRECOM
Quantity:
637
Part Number:
S-1000C18-N4T1G
Manufacturer:
SII/精工
Quantity:
20 000
Part Number:
S-1000C20-I4T1G
Manufacturer:
SII
Quantity:
5 288
Company:
Part Number:
S-1000C22-N4T1G
Quantity:
461
Part Number:
S-1000C23-14T1G
Manufacturer:
SEK
Quantity:
5 000
Part Number:
S-1000C23-14T1G
Manufacturer:
SEK
Quantity:
5 000
Part Number:
S-1000C23-I4T1G
Manufacturer:
SEK
Quantity:
20 000
Part Number:
S-1000C23-N4T1G
Manufacturer:
SII/精工
Quantity:
20 000
Part Number:
S-1000C27-I4T1U
Manufacturer:
SEIKOINST
Quantity:
12 461
Part Number:
S-1000C27-M5T1G
Manufacturer:
SII/精工
Quantity:
20 000
Company:
Part Number:
S-1000C31-I4T1G
Quantity:
249
SPECIFICATION
MODEL
OUTPUT
INPUT
PROTECTION
ENVIRONMENT
SAFETY &
EMC
OTHERS
NOTE
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVERLOAD
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
MTBF
DIMENSION
PACKING
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
RIPPLE & NOISE (max.)
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
EMI CONDUCTION & RADIATION
100W Single Output Switching Power Supply
Note.3
Note.2
S-100-3
3V
20A
0 ~ 20A
60W
100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p
2.85 ~ 3.3V 4.75 ~ 5.5V 6.75 ~ 8.25V 9 ~ 11V
200ms, 80ms at full load
24ms at full load
85 ~ 132VAC/180 ~ 264VAC selected by switch
47 ~ 63Hz
1.9A/115VAC
105 ~ 150% rated output power (130 ~ 180% of rated output power for S-100-5, S-100-36 ; 150 ~ 200% of rated output power for S-100-7.5 )
Protection type : Shut down o/p voltage, re-power on to recover
-10 ~ +60
20 ~ 90% RH non-condensing
-20 ~ +85 , 10 ~ 95% RH
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
Design refer to UL1012
I/P-O/P:1.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
Design refer to FCC Part15 J Conduction Class B
322.4K hrs min.
199*98*38mm (L*W*H)
0.62Kg; 20pcs/13.6Kg/0.8CUFT
70%
COLD START 27A/115VAC
<1mA / 240VAC
2.0%
0.5%
0.5%
0.03%/
S-100-5
(0 ~ 50
5V
20A
0 ~ 20A
100W
78%
(Refer to output load derating curve)
2.0%
0.5%
0.5%
0.96A/230VAC
MIL-HDBK-217F (25 )
I/P-FG:1.5KVAC
S-100-7.5 S-100-10 S-100-12 S-100-15 S-100-18 S-100-24 S-100-27 S-100-36
7.5V
13.6A
0 ~ 13.6A 0 ~ 10A
102W
80%
1.0%
0.5%
0.5%
54A/230VAC
10V
10A
100W
80%
1.0%
0.3%
0.3%
O/P-FG:0.5KVAC
12V
8.5A
0 ~ 8.5A
102W
10.8 ~ 13.2V 13.5 ~ 16.5V 16.2 ~ 19.8V 21.6 ~ 26.4V 26 ~ 32V 32.4 ~ 39.6V 43.2 ~ 52.8V
81%
1.0%
0.3%
0.3%
255 ~ 370VDC
15V
6.7A
0 ~ 6.7A
100.5W
81%
1.0%
0.3%
0.3%
18V
5.6A
0 ~ 5.6A
100.8W
82%
1.0%
0.3%
0.3%
24V
4.5A
0 ~ 4.5A
108W
84%
1.0%
0.2%
0.2%
S - 1 0 0
27V
3.7A
0 ~ 3.7A
99.9W
84%
1.0%
0.2%
0.2%
File Name:S-100-SPEC 2008-04-10
36V
2.7A
0 ~ 2.7A
97.2W
84%
1.0%
0.2%
0.2%
s e r i e s
S-100-48
48V
2A
0 ~ 2A
96W
84%
1.0%
0.2%
0.2%

Related parts for S-100

S-100 Summary of contents

Page 1

... INRUSH CURRENT (Typ.) COLD START 27A/115VAC LEAKAGE CURRENT <1mA / 240VAC 105 ~ 150% rated output power (130 ~ 180% of rated output power for S-100-5, S-100-36 ; 150 ~ 200% of rated output power for S-100-7.5 ) PROTECTION OVERLOAD Protection type : Shut down o/p voltage, re-power on to recover -10 ~ +60 WORKING TEMP ...

Page 2

... INPUT VOLTAGE (V) 60Hz File Name:S-100-SPEC 2008-04- Unit:mm Assignment DC OUTPUT -V DC OUTPUT +V fosc : 25KHz +V -V Ta=25 350 300 250 200 150 100 50 125 130 ...

Related keywords