V3P3 - 10mV
These internal clocks can be adjusted for various programmable rates which affect device functionality.
Refer to the 78M6631 Programmer’s Reference Manual for more information regarding the
programmability of the 78M6631 PLL and internal clock generation modules.
1.10 Oscillator
The 78M6631 oscillator drives a standard 32.768 kHz quartz crystal. These crystals are accurate and do
not require a high-current oscillator circuit. The 78M6631 oscillator has been designed specifically to
handle these crystals and is compatible with their high impedance and limited power handling capability.
The oscillator is powered directly and only from V3P3D, which therefore must be connected to a DC
voltage source not to exceed 4 V.
1.11 PLL and Internal Clock Generation
Timing for the device is derived from the 32.768 kHz crystal oscillator output. The PLL and on-chip timing
functions provide several clocks which include:
1.12 Real-Time Clock (RTC)
The RTC circuit is driven directly by the crystal oscillator. The RTC consists of a counter chain and output
registers. The counter chain consists of registers for seconds, minutes, hours, day of week, day of month,
month, and year (including leap years). Refer to the 78M6631 Programmer’s Reference Manual for more
information regarding the use of the 78M6631 RTC.
1.13 Hardware Watchdog Timer
Figure 3: Functions Defined by V1
Rev 1
400mV
V3P3 -
The MPU clock (CKMPU)
The emulator clock (2 x CKMPU)
The clock for the CE (CKCE)
The delta-sigma ADC and FIR clock(CKADC, CKFIR)
VBIAS
V3P3
0V
Since the oscillator is self-biasing, an external resistor must not be connected across the crystal.
V1
operation,
enabled
Normal
Battery
WDT dis-
modes
WDT
abled
In addition to the basic watchdog timer included in the 80515 MPU, an
independent, robust, fixed-duration, watchdog timer (WDT) is included in
the device. It uses the crystal oscillator as its time base and must be
refreshed by the MPU firmware at least every 1.5 seconds. When not
refreshed on time the WDT overflows, and the part is reset as if the RESET
pin were pulled high, except that the IORAM bits are maintained. 4096
oscillator cycles (or 125 ms) after the WDT overflow, the MPU is launched
from program address 0x0000. Asserting ICE_E deactivates the WDT.
The WDT can also be disabled by connecting the V1 pin to V3P3D. This
also deactivates V1 power fault detection. Since there is no method in
firmware to disable the crystal oscillator or the WDT, it is guaranteed that
whatever state the part might find itself in, upon watchdog overflow, the part
is reset to a known state.
11