ADM206 Analog Devices, ADM206 Datasheet - Page 10

no-image

ADM206

Manufacturer Part Number
ADM206
Description
0.1 uF/ +5 V Powered CMOS RS-232 Drivers/Receivers
Manufacturer
Analog Devices
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ADM206AR
Manufacturer:
ROHM
Quantity:
8 000
Part Number:
ADM206AR
Manufacturer:
VPT
Quantity:
2
Part Number:
ADM206AR
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
ADM206ARSZ
Manufacturer:
NS
Quantity:
6 241
Part Number:
ADM206ARSZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
ADM206ARZ
Manufacturer:
AD
Quantity:
12 191
Part Number:
ADM206ARZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
ADM206EAR
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
ADM206EARREEL
Manufacturer:
INF
Quantity:
3 193
Part Number:
ADM206EARZ
Manufacturer:
Silicon
Quantity:
36
ADM205–ADM211/ADM213
Transmitter (Driver) Section
The drivers convert TTL/CMOS input levels into EIA-232-E
output levels. With V
load, the output voltage swing is 9 V. Even under worst case
conditions the drivers are guaranteed to meet the 5 V EIA-232-E
minimum requirement.
The input threshold levels are both TTL and CMOS compat-
ible with the switching threshold set at V
V
puts may be left unconnected, as an internal 400 k pull-up re-
sistor pulls them high forcing the outputs into a low state.
As required by the EIA-232-E standard, the slew rate is limited
to less than 30 V/ s without the need for an external slew limit-
ing capacitor and the output impedance in the power-off state is
greater than 300 .
Receiver Section
The receivers are inverting level shifters which accept EIA-232-E
input levels ( 5 V to 15 V) and translate them into 5 V TTL/
CMOS levels. The inputs have internal 5 k pull-down resistors
to ground and are also protected against overvoltages of up to
mum and 2.4 V maximum which are well within the 3 V
EIA-232-E requirement. The low level threshold is deliberately
positive as it ensures that an unconnected input will be inter-
preted as a low level.
The receivers have Schmitt trigger inputs with a hysteresis level
of 0.5 V. This ensures error-free reception for both noisy inputs
and for inputs with slow transition times.
Shutdown (SD)
The ADM205, ADM206, ADM211 and ADM213 feature a
control input which may be used to disable the part and reduce
the power consumption to less than 5 W. This is very useful in
battery operated systems. During shutdown the charge pump is
turned off, the transmitters are disabled and all receivers except
R4 and R5 on the ADM213 are put into a high-impedance dis-
abled state. Receivers R4 and R5 on the ADM213 remain en-
abled during shutdown. This feature allows monitoring external
activity such as ring indicator monitoring while the device is in a
low power shutdown mode. The shutdown control input is ac-
tive high on all parts except the ADM213 where it is active low.
Refer to Tables II and III.
30 V. The guaranteed switching thresholds are 0.8 V mini-
CC
= 5 V the switching threshold is 1.25 V typical. Unused in-
CC
= +5 V and driving a typical EIA-232-E
CC
/4. With a nominal
–10–
Enable Input
The ADM205, ADM209, ADM211, and ADM213 feature an
enable input used to enable or disable the receiver outputs. The
enable input is active low on the ADM205, ADM209, ADM211
and active-high on the ADM213. Refer to Tables II and III.
When disabled, all receiver outputs are placed in a high imped-
ance state. This function allows the outputs to be connected di-
rectly to a microprocessor data bus. It can also be used to allow
receivers from different devices to share a common data line.
The timing diagram for the enable function is shown in Figure
25.
APPLICATION HINTS
Driving Long Cables
In accordance with the EIA-232-E standard, long cables are
permissible provided that the total load capacitance does not ex-
ceed 2500 pF. For longer cables which do exceed this, then it is
possible to trade off baud rate vs. cable length. Large load ca-
pacitances cause a reduction in slew rate, and hence the maximum
transmission baud rate is decreased. The ADM205–ADM211 and
ADM213 are designed so that the slew rate reduction with in-
creasing load capacitance is minimized.
For the receivers, it is important that a high level of noise immu-
nity be inbuilt so that slow rise and fall times do not cause mul-
tiple output transitions as the signal passes slowly through the
transition region. The ADM205–ADM211 and ADM213 have
0.5 V of hysteresis to guard against this. This ensures that, even
in noisy environments, error-free reception can be achieved.
High Baud Rate Operation
The ADM205–ADM211 and ADM213 feature high slew rates
permitting data transmission at rates well in excess of the
EIA-232-E specification. The drivers maintain 5 V signal
levels at data rates up to 120-kB/s under worst-case loading
conditions.
EN
R
OUT
*
3V
0V
* POLARITY OF EN IS REVERSED FOR ADM213
T
EN
Figure 25. Enable Timing
3.5V
0.8V
T
DIS
V
V
OH
VOL
REV. 0
– 0.1V
+ 0.1V

Related parts for ADM206