LM9073T National Semiconductor, LM9073T Datasheet - Page 13

no-image

LM9073T

Manufacturer Part Number
LM9073T
Description
Dual High Current Low-Dropout System Regulator
Manufacturer
National Semiconductor
Datasheet
Application Information
To initiate the Keep-Alive routine before actual power down,
it is important for the system controller to know when the sys-
tem has been switched OFF. To eliminate any interface be-
tween the controller and the ON/OFF switch and potentially
noisy unregulated input supply, and simple logic scheme
shown in Figure 6 can be used. With this circuitry the Reset
output form the LM9073 provides the ON/OFF sensing input
to the controller.
When switched OFF, the main regulator output will fall out of
regulation and generate a low logic level on the Reset out-
put. This input to the controller provides the switch OFF indi-
cation and initiates the Keep-Alive interval.
Control of the Keep-Alive duration is set by a logic 1 on the
Keep-Alive output line from the system controller. This high
(Continued)
Figure 5. Basic Keep-Alive Operation
13
level prevents the Reset output from resetting the entire sys-
tem and also gates the Keep-Alive input signal to the
LM9073. The inverted Reset signal provides a logic 1 to the
Keep-Alive input of the LM9073.
The Main output will only drop out of regulation for a very
short time before the Keep-Alive input turns it back on.
The Reset output remains low for the delay time interval.
When it turns high the Main output switches OFF and back
ON again very quickly. This continues until the system con-
troller takes the Keep-Alive output line to a logic low level.
DS101296-20
www.national.com

Related parts for LM9073T