PCF1171CU Philips Semiconductors, PCF1171CU Datasheet - Page 5

no-image

PCF1171CU

Manufacturer Part Number
PCF1171CU
Description
4-digit LCD car clock
Manufacturer
Philips Semiconductors
Datasheet
Philips Semiconductors
Time correction 2 minutes, switch S3
This switch operates in two ranges:
When switch S3 is pressed in these ranges, the minutes
and seconds are reset to zero. For displayed
time
incremented by one.
INPUT OPTIONS
In the description below S4, S5 and S6 refer to the external
switches shown in Fig.5 rather than to the corresponding
inputs.
In a real application, these inputs will normally be bonded
to the appropriate level to give the required function mode.
Internal/external regulation, switch S4
For internal regulation, S4 is closed, the internal voltage
regulator is active and the voltage supply for the LCD is
regulated to 5 V. For external regulation, S4 is open and
the circuit has to be supplied with an externally regulated
voltage.
LIMITING VALUES
In accordance with the Absolute Maximum Rating System (IEC 134).
Note
1. Connecting the supply voltage with reverse polarity, will not harm the circuit, provided the current is limited to 10 mA
HANDLING
Inputs and outputs are protected against electrostatic discharges in normal handling. However, to be totally safe, it is
advisable to take handling precautions appropriate to handling MOS devices. Advice can be found in
“Data Handbook IC16, General, Handling MOS Devices” .
1997 Apr 16
V
V
T
T
SYMBOL
Displayed time
Displayed time
amb
stg
DD
I
4-digit LCD car clock
by the external resistor.
58 minutes 00 seconds, the hour is also
supply voltage with respect to V
regulation disconnected;
all input voltages
operating ambient temperature
storage temperature
58 minutes 00 seconds
1 minute 59 seconds.
PARAMETER
SS
with internal
5
12/24-hour mode, switch S5
For 12-hour display mode, S5 is connected to V
For 24-hour display mode, S5 is connected to V
Single/continuous correction mode, switch S6
For single-set correction mode, S6 is connected to V
Each closure of S1 or S2 advances the counter by one.
For continuous-set correction mode, S6 is connected to
V
increments as for single-set correction mode. If S1 or S2 is
kept closed for more than 1s, the counter is automatically
incremented by 1 for each full second that S1 or S2 is kept
closed.
TESTING
In normal operation the test inputs TR (pin 38) and TS
(pin 39) have to be connected to V
frequency (64 Hz) is available at BP (pin 5). The test mode
is activated by connecting TS to V
frequencies are then increased by a factor of 65536.
In this mode the maximum input frequency is 100 kHz
(external generator at OSC IN). By connecting TR to V
all counters (seconds, minutes and hours) are stopped.
After connecting TR to V
state.
The switches/inputs described above also operate in the
test mode.
SS
note 1
. Momentary closure of S1 or S2 causes single
CONDITIONS
V
40
55
SS
DD
MIN.
all counters start from an initial
0.3
SS
8
V
+85
+125
DD
DD
MAX.
Product specification
(pin 20). All output
(pin 23). A test
PCF1171C
+ 0.3
V
V
C
C
DD
SS
UNIT
.
.
DD
SS
.

Related parts for PCF1171CU