LM80 National Semiconductor, LM80 Datasheet - Page 11

no-image

LM80

Manufacturer Part Number
LM80
Description
Serial Interface ACPI-Compatible Microprocessor System Hardware Monitor
Manufacturer
National Semiconductor
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LM8050J
Manufacturer:
ON
Quantity:
5 000
Part Number:
LM80644X01
Manufacturer:
NS/国半
Quantity:
20 000
Part Number:
LM809LDX-2.63
Manufacturer:
NS/国半
Quantity:
20 000
Part Number:
LM809M3-2.45
Manufacturer:
NSC
Quantity:
1 102
Part Number:
LM809M3-2.45
Manufacturer:
NS/国半
Quantity:
20 000
Part Number:
LM809M3-2.63
Quantity:
569
Part Number:
LM809M3-2.63
Manufacturer:
NS/国半
Quantity:
20 000
Part Number:
LM809M3-2.93
Manufacturer:
NS/国半
Quantity:
20 000
Part Number:
LM809M3-2.93/NOPB
Manufacturer:
TI
Quantity:
6 000
Part Number:
LM809M3-3.08/NOPB
Quantity:
1 500
Part Number:
LM809M3-4,38/NOPB
Quantity:
8 000
Company:
Part Number:
LM809M3-4.00
Quantity:
509
Company:
Part Number:
LM809M3-4.00
Quantity:
509
Functional Description
2.2 Serial Bus Interface
The Serial Bus control lines consists of the SDA (serial data),
SCL (serial clock) and A0-A1 (address) pins. The LM80 can
only operate as a slave. The SCL line only controls the serial
interface, all other clock functions within LM80 such as the
ADC and fan counters are done with a separate asynchro-
nous internal clock.
When using the Serial Bus Interface a write will always con-
sist of the LM80 Serial Bus Interface Address byte, followed
by the Internal Address Register byte, then the data byte.
There are two cases for a read:
1. If the Internal Address Register is known to be at the de-
sired Address, simply read the LM80 with the Serial Bus
Interface Address byte, followed by the data byte read
from the LM80.
(c) Serial Bus Read from a Register with the Internal Address Register Preset to Desired Location
(a) Serial Bus Write to the Internal Address Register followed by the Data Byte
(b) Serial Bus Write to the Internal Address Register Only
(Continued)
FIGURE 5. Serial Bus Timing
11
2. If the Internal Address Register value is unknown, write
The default power on Serial Bus address for the LM80 is:
0101(A2)(A1)(A0) binary, where A0-A2 reflect the state of
the pins defined by the same names.
All of these communications are depicted in the Serial Bus
Interface Timing Diagrams as shown in Figure 5 .
to the LM80 with the Serial Bus Interface Address byte,
followed by the Internal Address Register byte. Then re-
start the Serial Communication with a Read consisting of
the Serial Bus Interface Address byte, followed by the
data byte read from the LM80.