ADIS16204_07 AD [Analog Devices], ADIS16204_07 Datasheet - Page 4

no-image

ADIS16204_07

Manufacturer Part Number
ADIS16204_07
Description
Programmable High-g Digital Impact Sensor and Recorder
Manufacturer
AD [Analog Devices]
Datasheet
ADIS16204
Parameter
LOGIC INPUTS
DIGITAL OUTPUTS
SLEEP TIMER
START-UP TIME
FLASH MEMORY
CONVERSION RATE
POWER SUPPLY
1
2
3
4
5
6
Note that gravity can impact this number, zero-g condition assumes both axes oriented normal to the earth’s gravity.
Self-test response changes as the square of VDD.
Note that the inputs are +5 V tolerant.
Guaranteed by design.
Endurance is qualified as per JEDEC Standard 22, Method A117 and measured at −40°C, +25°C, +85°C, and +105°C.
Retention lifetime equivalent at junction temperature (T
Input High Voltage, V
Input Low Voltage, V
Logic 1 Input Current, I
Logic 0 Input Current, I
Input Capacitance, C
Output High Voltage, V
Output Low Voltage, V
Timeout Period
Initial
Reset recovery
Endurance
Data Retention
Maximum Throughput Rate
Minimum Throughput Rate
Operating Voltage Range, VDD
Power Supply Current
5
3
6
4
INL
IN
INH
OL
INH
INL
OH
J
), 55°C as per JEDEC Standard 22, Method A117. Retention lifetime decreases with junction temperature.
Conditions
V
V
I
I
T
Normal mode, SMPL_TIME ≥ 0x08
(f
Fast mode, SMPL_TIME ≤ 0x07
(f
Sleep mode, at 25°C
SOURCE
SINK
IH
IL
J
s
s
= 85°C
≤ 910 Hz), at 25°C
≥ 1024 Hz), at 25°C
= 0 V
= VDD
= 1.6 mA
= 1.6 mA
Rev. 0 | Page 4 of 24
Axis
2.0
0.5
20,000
20
Min
2.4
3.0
Typ
±0.2
−40
10
130
2.5
4096
2.066
3.3
12
37
150
Max
0.8
±1
−60
0.4
128
3.6
15
43
Unit
V
V
μA
μA
pF
V
V
Seconds
ms
ms
Cycles
Years
SPS
SPS
V
mA
mA
μA

Related parts for ADIS16204_07