BP1.2-6-T1 B B Battery, BP1.2-6-T1 Datasheet

BATT SEALED LEAD ACID 6V 1.2AH

BP1.2-6-T1

Manufacturer Part Number
BP1.2-6-T1
Description
BATT SEALED LEAD ACID 6V 1.2AH
Manufacturer
B B Battery
Series
BPr
Datasheet

Specifications of BP1.2-6-T1

Voltage - Rated
6V
Capacity
1.2Ah
Size / Dimension
3.82" L x 0.98" W x 2.01" H (97mm x 25mm x 51mm)
Termination Style
Spade, .187" (4.7mm)
Rechargeability
Yes
Weight
0.66 lb (299.37g)
For Use With
BVW063800003N - BATTERY CHG UNIV 6VDC @ 3.8A271-2389 - BATTERY CHG UNIV 6VDC @ 3.8A271-2384 - BATTERY CHG UNIV 6VDC @ 2A271-2383 - BATTERY CHG UNIV 6VDC @ 1A271-2379 - BATTERY CHG 120VAC 6VDC @ 600MA271-2377 - BATTERY CHG 120VAC 6VDC @ 400MAPATC-01 - BATTERY CHARGER 6 VOLT 1.5 AMP
Lead Free Status / RoHS Status
Contains lead / RoHS compliant by exemption
Other names
522-1000
BP1.2-6T1
F.V.
(V/cell)
F.V.
(V/cell)
Constant power discharge characteristics at 25 C/77 F
Constant current discharge characteristics at 25 C/77 F
DIMENSION(mm/inch)
FEATURES
SPECIFICATIONS
Nominal Voltage
Nominal Capacity
Approx. Weight
Terminals
Internal Resistance
Max. Discharge Current
Max. Charge Current
Operating Temperature Range
Container Material
A/1
Maintenance free(no water topping-up required).
No free acid(Non-spillable battery).
Low self-discharge rate, lower than 3% capacity loss per month.
Can be used in any orientation(excluding used inverted).
Absorbent Glass Mat technology for efficient gas recombination.
1.80V
1.75V
1.70V
1.65V
1.60V
1.80V
1.75V
1.70V
1.65V
1.60V
All data shall be changed without prior notice, BB reserves the right to explain and update the information contained hereinto.
Container Height
Total Height
97±1.5
25±1.5
51±1.5
56±2.0
Width
Length
Discharge
Discharge
REV. Feb. 2011
Time
Time
(3.82±0.06)
(0.98±0.06)
(2.01±0.06)
(2.20±0.08)
VRLA Rechargeable Battery
BP1.2-6
5 Min
5 Min
21.69
25.11
26.68
27.88
28.80
3.91
4.61
4.89
5.28
5.11
10 Min
10 Min
15.97
17.30
17.92
18.35
18.72
2.81
3.05
3.16
3.23
3.30
OUTER DIMENSIONS
15 Min
15 Min
12.80
13.39
13.80
14.12
14.40
2.23
2.33
2.40
2.46
2.50
97 1.5(3.82 0.06)
Charge 0 C~40 C(32 F~104 F)
Discharge -20 C~50 C(-4 F~122 F)
Storage. -20 C~40 C(-4 F~104 F)
(BP1.2-6FR)
6 V
1.2Ah @ 20 hour rate F.V.(1.75V/cell)
300g(0.66lbs.)
T1 (Faston Tab 187)
18 A (5 sec.)
0.36 A
ABS(UL94-HB, UL94-V0 is optional)
55m
30 Min
30 Min
1.291
1.340
1.370
1.389
1.403
7.61
7.90
8.08
8.20
8.28
(Fully Charged )
o
o
o
o
o
o
0.734
0.756
0.770
0.779
0.787
4.367
4.498
4.579
4.634
4.680
APPLICATION
1 Hr
1 Hr
o
UPS
Security
Medical
Lojack
o
o
o
o
25 1.5(0.98 0.06)
o
o
o
Unit: W
Unit: A
1.749
1.784
1.800
1.813
1.823
o
0.291
0.297
0.300
0.302
0.304
3 Hr
3 Hr
o
Powered by
TERMINAL TYPE
1.206
1.224
1.231
1.235
1.239
0.201
0.204
0.205
0.206
0.206
5 Hr
5 Hr
Measures
Terminal T1
B.B. Battery Co., Ltd.
3.2(0.13)
6.35(0.25)
Technology
ISO14001
ISO 9001
10 Hr
10 Hr
0.674
0.684
0.687
0.689
0.689
0.112
0.114
0.115
0.115
0.115
CE
IEC 61056-1
JIS C 8702-1
GB/T 19639.1
UL
Values
20 Hr
20 Hr
0.059
0.060
0.060
0.060
0.060
0.355
0.360
0.360
0.360
0.360
Innovation

Related parts for BP1.2-6-T1

Related keywords