HRPG-200_11 MEANWELL [Mean Well Enterprises Co., Ltd.], HRPG-200_11 Datasheet - Page 3

no-image

HRPG-200_11

Manufacturer Part Number
HRPG-200_11
Description
200W Single Output with PFC Function
Manufacturer
MEANWELL [Mean Well Enterprises Co., Ltd.]
Datasheet
1.Remote Control
2.Remote Sense
The remote sensing compensates voltage drop on the
Function Description of CN100
Function Manual
The PSU can be turned ON/OFF by using the "Remote
ON/OFF" function
load wiring up to 0.5V.
Between RC-(pin2) and RC+(pin1)
SW ON (Short)
SW OFF (Open)
Pin No. Function Description
1
2
3
4
5
6
AUXG
RC+
AUX
RC-
+S
-S
200W Single Output with PFC Function
Turns the output on and off by electrical or dry contact between pin 2 (RC-). Short: Power OFF, Open: Power ON.
Remote control ground.
Auxiliary voltage output, 4.75~5.25V, reference to pin 4(AUXG). The maximum load current is 0.3A. This output has the built-in oring
diodes and is not controlled by the "remote ON/OFF control".
Auxiliary voltage output ground. The signal return is isolated from the output terminals (+V & -V).
Positive sensing. The +S signal should be connected to the positive terminal of the load. The +S and -S leads should be twisted in pair to
minimize noise pick-up effect. The maximum line drop compensation is 0.5V.
Negative sensing. The -S signal should be connected to the negative terminal of the load. The -S and +S leads should be twisted in pair to
minimize noise pick-up effect. The maximum line drop compensation is 0.5V.
Output Status
OFF
ON
(Pin6)
-S
-V
-V
-
-
-V
-V
Fig 1.1
Fig 2.1
LOAD
LOAD
+V
+V
+
+
+V
+V
+S
(Pin5)
CN100
CN100
Sense lines should
be twisted in pairs
1 3 5
2 4 6
1 3 5
2 4 6
H R P G - 2 0 0
1
2
1
2
RC+
RC+
RC-
RC-
CN100
AUXG
CN100
AUXG
AUX
AUX
File Name:HRPG-200-SPEC 2011-08-09
+S
+S
-S
-S
5
6
5
6
SW
s e r i e s