Specifications of NP4-12

Voltage - Rated
12V
Capacity
4.0Ah
Size / Dimension
3.54" L x 2.76" W x 4.21" H (90mm x 70mm x 107mm)
Termination Style
Spade, .187" and .250" (4.7mm and 6.3mm)
Rechargeability
Yes
Brand/series
NP Series
Chemical System
Lead Acid
Dimensions
90mmL×70mmW×106mmH
Primary Type
Rechargeable
Resistance, Internal
40 Milliohms
Size
Rectangular
Temperature, Operating
-15 to +50 °C
Temperature, Operating, Maximum
+50 °C (Charge), +60 °C (Discharge)
Temperature, Operating, Minimum
-15 °C (Charge), -20 °C (Discharge)
Termination
0.187/0.25 Quick Disconnect Tab
Voltage, Nominal
12 V
Voltage, Rating
12 V
Weight
1.75 kg
Lead Free Status / RoHS Status
Contains lead / RoHS compliant by exemption
Other names
Q4855529
www.enersys.com
CYCLE SERVICE LIFE IN RELATION TO DEPTH OF DISCHARGE NP SERIES
RELATIONSHIP BETWEEN CHARGING VOLTAGE AND TEMPERATURE
TESTING CONDITIONS: DISCHARGE CURRENT:
EnerSys
P.O. Box 14145
Reading, PA 19612-4145
USA
Tel: +1-610-208-1991
+1-800-538-3627
CHARGING CURRENT:
CHARGING VOLUME:
Ambient Temperature
Number of Cycles
TEMPERATURE:
AMBIENT
0.17C Amp. (F.V. 1.7V/CELL)
0.09C Amp.
125% OF DISCHARGED
CAPACITY
20 º C (68 º F TO 77 º F)
EnerSys Europe
Zurich, Switzerland
Tel: +41 (0) 44 215 74 10
EnerSys Asia
Guangdong, China
Tel: +86 755 2689 3639
DISCHARGE CHARACTERISTICS
Curves at 25
NP SERIES
º
C (77
º
F)
TESTING CONDITIONS: FLOATING VOLTAGE: 2.25 TO 2.30V/CELL
FLOAT SERVICE LIFE NP SERIES
CHARGING CHARACTERISTICS
AMBIENT TEMPERATURE: 20 º C TO 22 º C (68 º F TO 72 º F)
Charging Time (Hours)
Life (Year)
Distributed by: