H3CR-A-300 OMRON [Omron Electronics LLC], H3CR-A-300 Datasheet - Page 20

no-image

H3CR-A-300

Manufacturer Part Number
H3CR-A-300
Description
Solid-state Multi-functional Timer
Manufacturer
OMRON [Omron Electronics LLC]
Datasheet
2. Signal Start/Instantaneous Operation/
Time-limit Reset
E Mode: Interval
1. Power-ON Start/Instantaneous Operation/
Time-limit Reset
This function is useful for the operation of a machine for a specified
period after power is ON.
B-128
Control output: NC (8 and 11)
Control output: NO (9 and 11)
Control output: NC (8 and 11)
Control output: NO (9 and 11)
Power (2 and 10)
Power (2 and 10)
Power indicator
Start (2 and 6)
Start (2 and 6)
NC (1 and 4)
NO (1 and 3)
NC (1 and 4)
NO (1 and 3)
Externally short-circuited
Solid-state Multi-functional Timer
Start signal (NO to NC to NO)
(Power continuously supplied)
Lit
Power
supply
Power
supply
Flashing
Lit
H3CR-A
2. Signal Start/Instantaneous Operation/
Time-limit Reset
This function is useful for the repetitive control such as the filling of
liquid for a specified period after each Signal start input.
Control output: NC (8 and 11)
Control output: NO (9 and 11)
Power (2 and 10)
Start (2 and 6)
NC (1 and 4)
NO (1 and 3)
Start signal
(Power continuously supplied)
t
Power
supply
t

Related parts for H3CR-A-300