RS-2405/H2 RECOM [Recom International Power], RS-2405/H2 Datasheet - Page 2

no-image

RS-2405/H2

Manufacturer Part Number
RS-2405/H2
Description
2 Watt SIP8 Isolated Single & Dual Output
Manufacturer
RECOM [Recom International Power]
Datasheet
ECONOLINE
DC/DC-Converter
Description
High power-density covering the temperature range -40°C to +85°C, offering extra features like Remote-
On-Off-function and Output-Filtering via 1 external capacitor only, are just some of the characteristics of this
converter, ideal for highly sophisticated industrial-designs.The RS series is available with isolation of 2kV or
3kV by chosing option "/H2" or "/H3".
Electrical Specifications
Input Voltage Range
Output Accuracy
Line Voltage Regulation
Load Voltage Regulation
(25% to 100% full load)
Output Ripple and Noise (20MHz limited)
Switching Frequency (at full Load)
Efficiency at Full Load
No Load Power Consumption
Isolation Voltage
Rated Working Voltage
Isolation Capacitance (1000V version)
Isolation Capacitance (H2 and H3)
Isolation Capacitance (1000V version)
Isolation Capacitance (H2 and H3)
Isolation Resistance
Short Circuit Protection
Operating Temperature Range
Storage Temperature Range
Relative Humidity
Package Weight
MTBF (+25°C)
Typical Characteristics
78
(+85°C)
}
Detailed Information see
Application Notes chapter "MTBF"
RS-24xx
(measured at T
MSL Level 1
Single output
Single output
Dual output
Dual output
Single output
Single & Dual output
(tested for 1 second)
H2
H3
(long term isolation)
Single
Single
Dual
Dual
Single output
Dual output
Dual output
A
= 25°C, at nominal input voltage and rated output current unless otherwise specified)
using MIL-HDBK 217F
using MIL-HDBK 217F
50mW min. / 139mW typ. / 250mW max.
120pF min. / 170pF typ. / 250pF max.
10pF min. / 40pF typ. / 60pF max.
5pF min. / 30pF typ. / 60pF max.
5pF min. / 30pF typ. / 60pF max.
April-2005
100kHz min. / 700kHz max.
see Application Notes
70% min. / 80% typ.
–50°C to +125°C
–55°C to +105°C
1398 x 10
–40°C to +85°C
210 x 10
1.000VDC min.
50mVp-p max.
2000VDC min.
3000VDC min.
±0.2% max.
±0.5% max.
±0.5% typ.
85kHz min.
Continuous
1GΩ min.
95% RH
3
3
hours
hours
±1%
±2%
4.8g
2:1
RS-types
Derating-Graph
(Ambient Temperature)
www.recom-international.com