HI-3588PCI HOLTIC [Holt Integrated Circuits], HI-3588PCI Datasheet - Page 7

no-image

HI-3588PCI

Manufacturer Part Number
HI-3588PCI
Description
Receiver with SPI Interface
Manufacturer
HOLTIC [Holt Integrated Circuits]
Datasheet
FUNCTIONAL DESCRIPTION (cont.)
TIMING DIAGRAMS
MASTER RESET (MR)
Assertion of Master Reset causes immediate termination of data
reception. The receive FIFO, Status Register FIFO flags and the
FIFO status RFLAG pin is also cleared. The Control Register is
not affected by Master Reset.
ARINC DATA
TXAOUT
TXBOUT
RFLAG
SCK
SCK
CS
CS
SO
SI
SO
CS
SI
t
CHH
BIT 31
DATA
Hi Impedance
ARINC BIT
BIT 30
t
SCKH
t
DS
BIT 32
NULL
t
RFLG
t
SCKL
DATA
t
MSB
t
SPI INSTRUCTION 08h
DV
RXR
MSB
BIT 31
t
CES
HOLT INTEGRATED CIRCUITS
DATA RATE - EXAMPLE PATTERN
NULL
SERIAL INPUT TIMING DIAGRAM
SERIAL OUTPUT TIMING DIAGRAM
t
t
CYC
CYC
t
t
SPIF
DH
RECEIVER OPERATION
ARINC
BIT 32
DATA
HI-3588
BIT 32
7
ARINC
BIT 31
NULL
t
SCKR
ARINC
BIT 30
t
* Above diagram does not apply for op code instruction 09hex
SCKF
WORD GAP
LSB
t
t
CEH
CHZ
LSB
NEXT WORD
ARINC
BIT 1
BIT 1
t
t
CPH
CPH
Hi Impedance

Related parts for HI-3588PCI