LPT40 ASTEC [Astec America, Inc], LPT40 Datasheet

no-image

LPT40

Manufacturer Part Number
LPT40
Description
40 Watts
Manufacturer
ASTEC [Astec America, Inc]
Datasheet
Special Features
• Universal input
• 3" x 5" footprint
• Less than 1U high
• Remote sense on main output
• Terminal Block option (-T)
• Built-in EMI filter
• Low output ripple
• Adjustable main output
• Overvoltage protection
• Overload protection
• 110 KHz switching frequency
• LPX40 enclosure kit available
Safety
UL
CSA
NEMKO EN 60950/EMKO-TUE
CB
CE
LPT40 Series
40 Watts
Total Power:
Input Voltage:
# of Outputs:
UL1950
E132002
CSA 22.2-234 Level 3
LR53982C
P95100411
(74-sec) 203
Certificate and report
1118, 1122, 1123, 1124
Mark (LVD)
40 - 55 Watts
85 - 264 VAC
120 - 300VDC
Triple
Electrical Specifications
Input
Input range
Frequency
Inrush current
Input current
Efficiency
EMI
Safety ground
leakage current
Output
Maximum Power
Cross regulation
Adjustment range
Hold-up time
Overload protection
Overvoltage protection
Remote sense
85-264 VAC
120-300 VDC
47-440 Hz
<18A peak @ 115VAC;
<36A peak @ 230VAC, cold start @ 25°C
1A max. (RMS) @ 115VAC
70% typical at full load (60% for LPT41)
FCC Class B conducted; CISPR 22 Class B conducted
EN55022 Class B conducted;
VDE 0878 PT3 Class B conducted
<0.5 mA @ 50/60 Hz, 264 VAC input
40W for convection (LPT41, 25W);
55W with 30CFW forced air (LPT41, 41W)
±2% on output 1; ±5% on outputs 2, 3
-5, +10% minimum
20ms @ 40W load, 115 VAC nominal line
Short circuit protection on all outputs. Case overload
protected @ 110% to 145% above peak rating
5.7 to 6.7 VDC on the main output
LPT41: 3.6 to 4.6VDC
Compensates for 0.5 V lead drop min. Will operate without
remote sense connected. Reverse connection protected.
RoHS
Embedded Power for
Business-Critical Continuity
Rev. 04.13.06
LPT40 Series
1 of 3

Related parts for LPT40

LPT40 Summary of contents

Page 1

... Overload protection protected @ 110% to 145% above peak rating 5.7 to 6.7 VDC on the main output Overvoltage protection LPT41: 3.6 to 4.6VDC Remote sense Compensates for 0.5 V lead drop min. Will operate without remote sense connected. Reverse connection protected. Embedded Power for Business-Critical Continuity Rev. 04.13.06 LPT40 Series RoHS ...

Page 2

... Embedded Power for Business-Critical Continuity 50mV 50mV 120mV 50mV 120mV 120mV 50mV 120mV 120mV 50mV 120mV 50mV 50mV 150mV 150mV 50mV 240mV 120mV 50mV 240mV 120mV Rev. 04.13.06 LPT40 Series ...

Page 3

... Embedded Power for Business-Critical Continuity Rev. 04.13.06 LPT40 Series Astec Power 5810 Van Allen Way Carlsbad, CA 92008 USA Telephone: +1 760 930 4600 Facsimile: +1 760 930 0698 Technical Support: +1 888 41 ASTEC or +1 407 241 2752 ...

Related keywords