LUCL8574DP-D AGERE [Agere Systems], LUCL8574DP-D Datasheet - Page 8

no-image

LUCL8574DP-D

Manufacturer Part Number
LUCL8574DP-D
Description
L8574D Resistive Subscriber Line Interface Circuit(SLIC), Ring Relay,and Protector(SRP)for Long Loop and TR-57 Applications
Manufacturer
AGERE [Agere Systems]
Datasheet
L8574D Resistive Subscriber Line Interface Circuit (SLIC), Ring
Relay, and Protector (SRP) for Long Loop and TR-57 Applications
Electrical Characteristics
Ring Trip Detector
Table 3. Ring Trip Detector
1. The ringing source consists of the ac and dc voltages added together (battery-backed ringing); the ringing return is battery ground.
2. Pretrip: ringing must not be tripped by a 10 k resistor in parallel with an 8 F capacitor applied across Tip and Ring.
Battery Feed
Table 4. Battery Feed
1. Assumes 2 x 200
2. When the current-limit circuit is active and the battery switch is off, the longitudinal current must be less than the dc loop current to ensure
3. Assumes C
4. Detector values are independent of office battery and are valid over the entire range of V
5. IEEE is a registered trademark of The Institute of Electrical and Electronics Engineers, Inc.
6. Assumes the external dc feed resistors are matched to 0.2% and proper battery noise cancellation; i.e., a 0.22 F capacitor from V
7. Assumes proper battery noise cancellation; i.e., a 0.22 F capacitor from V
8
Ringing Source
Ring Trip
Loop Resistance Range
Longitudinal Current Capability per Wire
dc Loop Current Limit (R
Current-limiter ac Output Impedance
Current-limiter Transient Current (in response to a step voltage
Switchhook Detector Loop Resistance
Longitudinal to Metallic Balance— IEEE
Metallic to Longitudinal (Harm) Balance
change on V
proper ac transmission.
on-hook (NSTAT = 1) if either V
thermal shutdown. The status of the thermal shutdown circuit is output on B3 when CS is high (thermal shutdown is a logic 0). V
V
one pin are shorted together):
— If V
— If V
(see Figure 5).
Frequency (f)
dc Voltage
ac Voltage
Loop Resistance
Trip Time (f = 20 Hz)
NSTAT Valid
I
200 Hz to 4 kHz
Off-hook (NSTAT = 0)
On-hook (NSTAT = 1)
200 Hz to 1 kHz
1 kHz to 3 kHz
200 Hz to 4 kHz
LOOP
BAT2
are defined as disconnected depending on the voltage at the power supply pins as follows (the pins of supplies that have more than
BAT1
BAT1
= 18 mA at V
2
(NSTAT = 0):
LIM
–20 V (i.e., more negative than –20 V) and V
–10 V (i.e., more positive than –10 V) or V
BF
= 33 nF; C
1
)
:
external dc feed resistors.
BAT2
LIM
1
= –42 V
LOOP
determines the ac output impedance of the current-limit circuit when it is active.
(3.17 dBm overload into 600 ):
BAT1
Parameter
Parameter
= 200 )
or V
BAT2
(continued)
3
is disconnected (open circuit) from its dc source and an off-hook (NSTAT = 0) if the L8574 is in
:
4
:
5
7
2
:
Std. 455
BAT2
BAT2
6
:
–10 V, then NSTAT must be on-hook (NSTAT = 1).
–20 V, then NSTAT must operate normally.
BF
to CBN (see Figure 5).
1840
4400
1840
26.5
Min
–36
Min
8.5
17
60
58
53
30
8
BAT1
and V
BAT2
3300
Typ
Typ
20
28
. However, NSTAT must indicate an
Lucent Technologies Inc.
2700
Max
Max
29.5
–57
105
200
150
28
80
25
October 1998
Data Sheet
mArms
BAT1
Vrms
BF
Unit
Unit
mA
mA
ms
ms
Hz
dB
dB
dB
V
to CBN
and

Related parts for LUCL8574DP-D