Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are abso-
lute stress ratings only. Functional operation of the device is not implied at these or any other conditions in excess
of those given in the operational sections of the data sheet. Exposure to absolute maximum ratings for extended
periods can adversely affect device reliability.
Note: The IC can be damaged unless all ground connections are applied before, and removed after, all other connections. Furthermore, when
5 V dc Supplies (V
High Office Battery Supply (V
Auxiliary Office Battery Supply (V
Ringing Voltage
Logic Input Voltage
Maximum Junction Temperature
Storage Temperature Range
Relative Humidity Range
Switch 1, 2, 3; Pole to Pole
Switch 4; Pole to Pole
Switch Input to Output
powering the device, the user must guarantee that no external potential creates a voltage on any pin of the device that exceeds the
device ratings. For example, inductance in a supply lead could resonate with the supply filter capacitor to cause a destructive overvolt-
age.
Parameter
CC
)
BAT1
)
BAT2
Full-Feature SLIC and Ringing Relay for TR-57 Applications
)
(at T
A
= 25 °C)
Symbol
–0.5
–0.5
Min
–75
–40
5
V
V
BAT1
CC
Max
165
125
320
465
320
110
7.0
0.5
+ 0.5 V
95
to 0.5 V
Vrms
Unit
°C
%
V
V
V
V
V
V
V
C
13