MPB125 POWER-ONE [Power-One], MPB125 Datasheet

no-image

MPB125

Manufacturer Part Number
MPB125
Description
High Power Density in Industry Standard 3 x 5 Footprint
Manufacturer
POWER-ONE [Power-One]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MPB125-1012
Manufacturer:
Ferraz-shawmut
Quantity:
1 000
Part Number:
MPB125-2012G
Manufacturer:
PowerOne
Quantity:
272
Part Number:
MPB125-2012G
Manufacturer:
MICROCHIP
Quantity:
6 171
Part Number:
MPB125-2024G
Manufacturer:
M/A-COM
Quantity:
5 000
Part Number:
MPB125-2048G
Manufacturer:
CYPRESS
Quantity:
15 629
FEATURES
• High Power Density in Industry Standard 3" x 5" Footprint
• Power Factor Correction (PFC) Meets EN61000-3-2
• Main Output Remote Sense
• Power Good Signals
• CE Marked to Low Voltage Directive
• Input Transient & ESD Compliance to
DESCRIPTION
The MPB125 series incorporates patented high efficiency circuitry,
high power density and active Power Factor Correction (PFC) to meet
the requirements of networking and data communications systems, as
well as commercial and industrial configurations.
Dual output units deliver a regulated main output plus a second 12V
output for fans or other system functions. Multiple output models
provide tightly regulated DC power in a variety of configurations.
The MPB125 is rated for convection as well as forced-air cooling. Full
REV. 08/23/01
MULTIPLE OUTPUT MODEL SELECTION CHART -
MPB125-2005
MPB125-2012
MPB125-2015
MPB125-2024
MPB125-2048
MPB125-3000
MPB125-4250
MPB125-4350
NOTES: 1) Maximum convection output power is 75 watts.
(NOTE 1)
(NOTE 1)
MODEL
EN61000-4-2/-3/-4/-5
80 Watts Convection Cooling, 125 Watts Forced-Air Cooling
2) Maximum forced-air output power is 125 watts with 130 LFM at 5 CFM.
3) Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth.
4) Maximum power of 80 watts from V1 + V2 with 130 LFM at 5 CFM forced-air cooling.
5) Maximum power of 45 watts from V1 + V2 for convection cooling.
NUCLEAR AND MEDICAL APPLICATIONS Power-One products are not authorized for use as critical components in life support systems,
equipment used in hazardous environments, or nuclear control systems without the express written consent of the President of Power-One, Inc.
TECHNICAL REVISIONS The appearance of products, including safety agency certifications pictured on labels, may change depending on the
date manufactured. Specifications are subject to change without notice.
VOLTAGE
OUTPUT
(VOLTS)
+2.5V
+3.3V
+12V
+12V
+12V
+15V
+12V
+24V
+12V
+48V
+12V
+12V
+12V
+12V
-12V
-12V
-12V
+5V
+5V
+5V
+5V
MAXIMUM OUTPUT
CURRENT (AMPS),
130 LFM (NOTE 2)
10A
15A
10A
15A
10.5A
0.5A
0.5A
8.3A
0.5A
5.2A
0.5A
2.6A
0.5A
0.5A
(NOTE 4,5)
(NOTE 4,5)
0.5A
(NOTE 4,5)
(NOTE 4,5)
0.5A
25A
15A
5A
5A
5A
MPB125 SERIES
1
output power is available with as few as 130 Linear Feet per Minute
(LFM) forced-air cooling.
The MPB125 product line is approved to the latest international
regulatory standards, and displays the CE Mark.
REGULATION
TOTAL
±3%
±5%
±3%
±5%
±3%
±5%
±3%
±5%
±3%
±5%
±3%
±5%
±3%
±3%
±3%
±5%
±3%
±3%
±3%
±5%
±3%
%
RIPPLE & NOISE
% pk-pk
(NOTE 3)
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
-11.64V to -12.36V
-11.64V to -12.36V
-11.64V to -12.36V
REGULATION RANGE
11.40V to 12.60V
11.64V to 12.36V
11.40V to 12.60V
14.54V to 15.45V
11.40V to 12.60V
23.28V to 24.72V
11.40V to 12.60V
46.56V to 49.44V
11.40V to 12.60V
11.40V to 12.60V
11.40V to 12.60V
11.40V to 12.60V
4.85V to 5.15V
4.85V to 5.15V
2.42V to 2.58V
4.85V to 5.15V
3.20V to 3.40V
4.85V to 5.15V

Related parts for MPB125

Related keywords