6125FA5A Cooper/Bussmann, 6125FA5A Datasheet

no-image

6125FA5A

Manufacturer Part Number
6125FA5A
Description
Manufacturer
Cooper/Bussmann
Datasheet

Specifications of 6125FA5A

Date_code
05+
Packing_info
1808-5A
Description
• Surface Mount
• Environmentally rugged, complies with the EIA-IS-722
• Solder Immersion Compatible
• Targeted for Consumer Electronics
• Overcurrent protection of systems up to 125VAC/DC
• Wire-in-air design
Agency Information
• UL Listed Guide and File Numbers (250mA-12A):
• UL Recognized Guide and File Numbers (15A):
• CSA Component Acceptance: 053787 C 000 &
Environmental Data
• Shock: MIL-STD-202, Method 213, Test Condition 1
• Vibration: MIL-STD-202, Method 201 (10-55 Hz, 0.06
• Salt Spray: MIL-STD-202, Method 101, Test Condition
• Insulation Resistance: MIL-STD-202, Method 302, Test
• Resistance to Solder Heat: MIL-STD-202, Method 210,
• Thermal Shock: MIL-STD-202, Method 107, Test
Ordering
• Specify product code and packaging code
* AC Interrupting Rating (Measured at designated voltage, 100% power factor); DC Interrupting Rating (Measured at designated voltage, time constant of less than 50
** DC Cold Resistance (Measured at 10% of rated current)
† Typical Melting I
‡ Typical Voltage Drop (Measured at rated current after temperature stabilizes)
Device designed to carry rated current for four hours minimum. An operating current of 80% or less of rated current is recommended, with further derating required at elevated
ambient temperatures.
Product
Code
6125FA250mA
6125FA375mA
6125FA500mA
6125FA750mA
6125FA1A
6125FA1.25A
6125FA1.5A
6125FA2A
6125FA2.5A
6125FA3A
6125FA3.5A
6125FA4A
6125FA5A
6125FA6.3A
6125FA7A
6125FA10A
6125FA12A
6125FA15A
Standard
JDYX & E195337
JDYX2 & E195337
Class No: 1422 30
(100 G’s peak for 6 milliseconds)
inch, total excursion)
B (48 hrs)
Condition A (After Opening) 10,000 ohms minimum
Test Condition F (20 sec, at 260° C)
Condition B (-65° C to +125° C)
microseconds, battery source)
% of Amp Rating
100%
200%
ELECTRICAL CHARACTERISTICS
2
t (Measured with a battery bank at rated DC voltage, 10x-rated current, time constant of calibrated circuit less than 50 microseconds)
125V
125V
125V
125V
125V
125V
125V
125V
125V
125V
125V
125V
125V
125V
125V
125V
125V
N/A
AC
Voltage
Rating
125V
125V
125V
125V
125V
125V
125V
125V
125V
125V
125V
125V
125V
125V
125V
N/A
N/A
N/A
DC
5 Seconds Maximum
4 Hours Minimum
Opening Time
86V
86V
86V
86V
86V
86V
86V
86V
86V
86V
86V
86V
86V
86V
86V
86V
86V
86V
DC
125V AC 125V DC 86V DC
SPECIFICATIONS
50A
50A
50A
50A
50A
50A
50A
50A
50A
50A
50A
50A
50A
50A
50A
50A
50A
N/A
Interrupting
Rating*
300A
300A
300A
300A
300A
300A
300A
300A
300A
300A
300A
300A
300A
300A
300A
N/A
N/A
N/A
Dimensions
Drawing Not to Scale
Land Pattern
Soldering Method
• Wave Solder: 260°C, 10 sec max.
• Infrared Reflow: 260°C, 30 sec max.
(0.102+.010)
2.59+ .250
End View
(MIL-STD-202, Method 210)
10,000A
10,000A
10,000A
10,000A
10,000A
10,000A
10,000A
10,000A
10,000A
10,000A
10,000A
10,000A
10,000A
10,000A
10,000A
10,000A
10,000A
10,000A
(0.053+ .010)
(0.102+.010)
(0.102+.010)
1.35+ .25
2.59+ .250
2.59+ .25
mm
Resistance
6125FA Series, Fast Acting
(ohms)**
(inches)
0.038
0.028
0.025
0.022
0.016
0.012
0.011
0.007
0.006
0.004
Typ.
0.65
0.36
0.24
0.15
0.11
0.09
0.07
0.05
(0.240+.010)
(0.102)
(0.339)
(0.053+.010)
6.10+.25
(0.102+.010)
2.6
8.6
1.35+.25
2.59+.25
(0.118)
3.0
Typical
Brick
Melt
0.01
0.03
0.06
0.07
0.14
0.24
0.41
0.80
14.0
19.0
124
I
1.4
2.4
3.3
4.4
7.8
44
69
2
t†
(0.053+.010)
(0.240+.010)
1.35+.25
6.10+.25
Side View
(0.157)
4.0
Drop (V)‡
Fuses
Voltage
Typical
0.114
0.107
0.103
0.098
0.30
0.25
0.22
0.17
0.17
0.16
0.15
0.15
0.14
0.13
0.13
0.13
0.12
0.12
(0.053+.010)
1.35 +.25
Top View

Related parts for 6125FA5A