... Product Highlights The M-FIAM3 front-end module that provides EMI filtering and transient protection. The M-FIAM3 enables designers using Vicor’s Maxi, Mini, Micro Series 300 V DC-DC converters to meet conducted emission/ conducted susceptibility per MIL-STD-461E; and input transients per MIL-STD-704E/F. The M-FIAM3 accepts an input voltage of 180 – ...
Page 2
... SPECIFICATIONS (typical 25°C, nominal line and 75% load, unless otherwise specified) BP INPUT SPECIFICATIONS Parameter Min Input voltage 180 Inrush limiting Transient immunity OUTPUT SPECIFICATIONS Parameter Min Output current Efficiency 96 Internal voltage drop External capacitance 10 CONTROL PIN SPECIFICATIONS Parameter Min ON/OFF control Enable (ON) 0 ...
Page 3
... MIL-STD-810F, Method 514.5, Procedure I, Category 14, Sine and Random vibration per Table 514.5C for Helicopter AH-6J Main Rotor with overall level of 5.6 G rms for 4 hours per axis. MIL-STD-810F, Method 514.5C, General Minimum Integrity Curve per Figure 514.5C-17 with overall level of 7.7 G rms for 1 hour per axis. ...
Page 4
... Component Suggestions Recommended Fuse: (F1 Max., Bussmann ABC style Capacitance: (C1)10 µF(min), 22 µF(max) Figure 4 – Basic connection diagram with Transient, Surge Protection and Recommended Reverse Polarity Protection. Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 Set your site on VICOR at vicorpower.com Figure 2 – Transient Immunity; M-FIAM3 output response to an input transient ...
Page 5
... DIA,(7X) 10,16 2,03 0.700 17,78 1.000 25,40 1.400 35,56 * Slotted baseplate only ** Threaded & through hole (style 2 & 3) baseplates *** Reserved for Vicor accessories. Not for mounting C L Pin center line INBOARD ONBOARD SOLDER SOLDER MOUNT MOUNT SHORT PIN STYLE LONG PIN STYLE 0.094 ±0.003 0.094 ± ...
Page 6
... Vicor does not assume any liability arising out of the application or use of any product or circuit; neither does it convey any license under its patent rights nor the rights of others. Vicor general policy does not recommend the use of its components in life support applications wherein a failure or malfunction may directly threaten life or injury. Per Vicor Terms and Conditions of Sale, the user of Vicor components in life support applications assumes all risks of such use and indemnifies Vicor against all damages ...