ICX055 SONY [Sony Corporation], ICX055 Datasheet - Page 12

no-image

ICX055

Manufacturer Part Number
ICX055
Description
1/3-inch CCD Image Sensor for PAL Color Camera
Manufacturer
SONY [Sony Corporation]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ICX055AK
Manufacturer:
BROADCOM
Quantity:
9 890
Part Number:
ICX055AK
Manufacturer:
SONY/索尼
Quantity:
20 000
Part Number:
ICX055AK-6
Manufacturer:
SONY/索尼
Quantity:
20 000
Part Number:
ICX055AK-A
Manufacturer:
ISO-TECH
Quantity:
43
Part Number:
ICX055AK-A
Manufacturer:
SANYO/三洋
Quantity:
20 000
Part Number:
ICX055BK-A
Manufacturer:
SONY
Quantity:
11
Part Number:
ICX055BKA
Manufacturer:
SONY
Quantity:
175
Part Number:
ICX055BL
Manufacturer:
TUNDRA
Quantity:
480
Part Number:
ICX055BL-A
Manufacturer:
ATMEL
Quantity:
720
7. Dark signal shading
8. Flicker
9. Line crawls
10. Lag
After measuring 6, measure the maximum (Ydmax [mV]) and minimum (Ydmin [mV]) values of the Y signal
output and substitute the values into the following formula.
1) Fy
Set to standard imaging condition II. Adjust the luminous intensity so that the average value of the Y signal
output is 200mV, and then measure the difference in the signal level between fields ( Yf [mV]). Then
substitute the value into the following formula.
Fy = ( Yf/200)
2) Fcr, Fcb
Set to standard imaging condition II. Adjust the luminous intensity so that the average value of the Y signal
output is 200mV, insert an R or B filter, and then measure both the difference in the signal level between
fields of the chroma signal ( Cr, Cb) as well as the average value of the chroma signal output (CAr, CAb).
Substitute the values into the following formula.
Fci = ( Ci/CAi)
Set to standard imaging condition II. Adjust the luminous intensity so that the average value of the Y signal
output is 200mV, and then insert a white subject and R, G, and B filters and measure the difference
between Y signal lines for the same field ( Ylw,
following formula.
Lci = ( Yli/200)
Adjust the Y signal output value generated by strobe light to 200mV. After setting the strobe light so that it
strobes with the following timing, measure the residual signal (Ylag). Substitute the value into the following
formula.
Lag = (Ylag/200)
Ydt = Ydmax – Ydmin [mV]
Strobe light
Output
timing
SG1
FLD
100 [%]
100 [%] (i = r, b)
100 [%] (i = w, r, g, b)
100 [%]
Light
Y signal output 200mV
– 12 –
Ylr,
Ylg,
Ylag (lag)
Ylb [mV]). Substitute the values into the
ICX055AK