Description
TONE/PULSE SWITCHABLE DIALER WITH LCD INTERFACE
Manufacturer
EMC [ELAN Microelectronics Corp]
Datasheet
* This specification are subject to be changed without notice.
Repertory memory
Storing of 3 sets memory
Dialing (after memory dialed out, the content of LNB is keeping to current data)
Pause (P) key operation
The Pause (P) key is designed to support pause operation in dialing duration. “P” key can be stored in memory
and it will occupy one digital position.
Storing : EM91203 series support two operating methods to store numbers into SAVE redial memory.
Method 1
• To select Pulse or Tone mode.
• Off-hook (or turn on HF function), push d1, d2, .. , dn. The numbers d1, d2, .. , dn will be dialed out in Pulse
• After dn had been dialed out and push [ST], Save key. If the keying numbers are more than 32 digits that
Method 2
Dialing :
• To select Pulse or Tone mode.
• Off-hook (or turn on HF function), push Save key. The numbers stored in SAVE memory will be dialed out
The EM91203 series incorporated several sets repertory memory and each one can store number up to 16 digits.
As in memory storing, if stored numbers are more than 16 digits that only the previous 16 digits can be stored
into specific memory. Otherwise, these numbers can be stored entirely. After memory dialed out, the content
of LNB is keeping to current data.
Direct (one-touch) operation
Off-hook (or turn on HF function), push ST, d1, d2, .. , dn [ST], EMn. The numbers d1, d2, .. , dn will be stored
into memory location “EMn”. The “EMn” expressed emergency memory EM1 to EM3.
Direct (one-touch) memory operation
• To select Pulse or Tone mode.
• Off-hook (or Turn on HF function), push EMn key. The numbers that are stored in direct memory location
or Tone mode as selection.
content of SAVE memory can not be updated. Otherwise, these numbers will be stored into SAVE memory.
In the [] key allows to be omitted.
Off-hook (or turn on HF function), push ST, d1, d2, .. , dn, [ST], Save. If the keying numbers are not over 32
digits, the numbers d1, d2, .. , dn will be stored in SAVE redial memory automatically.
in Pulse or Tone mode as selection.
EMn will be dialed out in Pulse or Tone mode as selection. The “n” expressed digital number from 1~3 decided
by dialers’ memory sets.
TONE/PULSE SWITCHABLE DIALER WITH LCD INTERFACE
EM91203 SERIES