KAC-1 COOPER [Cooper Bussmann, Inc.], KAC-1 Datasheet - Page 15

no-image

KAC-1

Manufacturer Part Number
KAC-1
Description
High Speed Fuses
Manufacturer
COOPER [Cooper Bussmann, Inc.]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
KAC-1310
Manufacturer:
TOSHIBA
Quantity:
1
Amp
Range
5-30
35-60
70-100
125-200
225-400
450-600
700-800
900-1000
1200
1mm = 0.0394” / 1” = 25.4mm
FWP
Fig. 1: 5-800A
Amps: — 5-1200A
Dimensions (in)
Specifications
Description: North American
style stud-mount fuses.
Dimensions: See Dimensions
illustrations.
Ratings:
Agency Information: CE, UL Recognition & CSA
Component Acceptance on 5-800A
Electrical Characteristics
Total Clearing I
The total clearing I
voltage and at power factor of
15% are given in the electrical
characteristics. For other volt-
ages, the clearing I
by multiplying by correction
factor, K, given as a function
of applied working voltage,
E g , (rms).
Volts: — 700Vac
A
D
IR: — 200kA RMS Sym.
High Speed Fuses
North American — FWP 700V: 5-1200A
E
B
C
— 50kA @700Vdc
Fig. A
1
1
1
1
1
1
1
2
3
G
F
2.870 0.563 1.855 2.4772.477 0.250 0.4050.063 0.250
4.375 0.813 2.750 3.7083.312 0.344 0.7250.125 0.542
4.406 0.947 2.594 3.6253.563 0.344 0.7500.125 0.375
5.090 1.500 2.840 4.1903.500 0.410 1.0000.250 0.750
5.090 2.000 2.840 4.2803.530 0.410 1.5000.250 0.780
7.090 2.500 2.840 5.7204.190 0.530 2.0000.380 1.300
6.630 2.000 2.844 5.5625.062 0.625 1.5000.250 0.875
See Drawing
See Drawing
J
H
2
B
t
2
Fig. 2: 900-1000A
7.594
2
t at rated
t is found
5.966
5.154
C
For product data sheets, visit www.cooperbussmann.com/products/datasheet.asp
3.500
3.844
0.625
D
1.375
1.5
1.0
0.5
0.3
0.2
0.15
E
316
1.031
K
2.750
2)
1)
0.5
F
3)
1) 35-100A Range
2) 125-600A Range
3) 700-1200A Range
460
9.590
Fig. 3: 1200A
G
4.250
6.840
604
H
3.500
700
1.625
1.750
I
3.844
0.500
0.125
0.625
E
10.844
0.750
g
• Watts loss provided at rated current.
• See accessories on page 106.
• Excellent dc performance
• Low arc voltage and low
• Superior cycling capability
Catalog
Numbers
FWP-5B
FWP-10B
FWP-15B
FWP-20B
FWP-25B
FWP-30B
FWP-35B
FWP-40B
FWP-50B
FWP-60B
FWP-70B
FWP-80B
FWP-90B
FWP-100B
FWP-125A
FWP-150A
FWP-175A
FWP-200A
FWP-225A
FWP-250A
FWP-300A
FWP-350A
FWP-400A
FWP-450A
FWP-500A
FWP-600A
FWP-700A
FWP-800A
FWP-900A
FWP-1000A
FWP-1200A
Arc Voltage
This curve gives the peak arc
voltage, U L , which may
appear across the fuse dur-
ing its operation as a function
of the applied working volt-
age, E g , (rms) at a power
factor of 15%.
Power Losses
Watts loss at rated current is
given in the electrical charac-
teristics. The curve allows
the calculation of the power
losses at load currents lower
than the rated current. The
correction factor, K p , is given
as a function of the RMS
load current, I b , in % of the
rated current.
Catalog Numbers
Features and Benefits
energy let-through (I
Rated
Current
RMS-Amps
1000
1200
100
125
150
175
200
225
250
300
350
400
450
500
600
700
800
900
10
15
20
25
30
35
40
50
60
70
80
90
5
2
t)
Electrical Characteristics
Pre-arc
120000
195000
10500
17600
23700
31000
36400
45200
66700
54000
78000
91500
1800
2900
4200
5500
7700
135
210
305
360
415
540
1.6
3.6
10
26
44
58
34
76
2
1.6
1.4
1.2
10
8
6
5
4
3
I
• DC common bus
• DC drives
• Power converters/rectifiers
• Reduced voltage starters
1.0
0.8
0.6
0.5
0.4
0.3
0.2
0.1
2
300
3
t (A
Typical Applications
30 40 50
K
2
U
1) 125-600A Range
2) 35-100 & 700-1200A Range
p
Sec)
1)
L
400
1100000
Clearing
at 700V
125000
137000
170000
250000
300000
450000
530000
600000
11700
16700
22000
31300
42500
71200
95600
2000
2400
2700
3500
7300
2)
180
340
450
160
320
600
950
10
20
75
60
500
70
107
122
125
140
150
170
190
Watts
Loss
80 90 100%
48
58
65
78
94
12
12
12
15.5
18
21
25
27
28
32
35
43
45
600
1.5
4
5.5
6
7
9
E
I
g
b
101
700

Related parts for KAC-1