EDS10-15F FUJI [Fuji Electric], EDS10-15F Datasheet - Page 4

no-image

EDS10-15F

Manufacturer Part Number
EDS10-15F
Description
FC SERIES SELF-BALANCING RECORDER
Manufacturer
FUJI [Fuji Electric]
Datasheet
4
CODE SYMBOLS
P F A
1 2 3 4 5 6 7 8
PFA
1
2
3
Notes: * (1) Cold junction compensation and burnout circuit
W
M
A
B
D
H
N
E
F
T
J
Y
1 -
(2) Minimum temperature range (span) of thermo-
(3) Alarm units are to be added consecutively from pen
(upscale) are provided with recorder for thermo-
couple input.
couple:
K: 150 C
E: 100 C
No. 1 to pen No. 3.
9 10 11 12 13
1
2
*
*
*
*
*
*
A
B
C
D
G
Y
E
F
*
*
H
D
Y
K
L
E
*
*
Y
K
H
D
E
L
*
*
H
D
Y
K
L
E
J: 100 C
R: 500 C
Number of recording points
1-pen
2-pen
3-pen
Input signal (*4)
1 to 5V DC
4 to 20mA DC
4mV DC span or more, max. voltage 30V
100 A DC span or more, max. current 200mA
Thermocouple input, 4mV span or more
Same as above, for connecting zener barrier
Resistance bulb JPt 100, 3-wire type, 50 C span or more
Same as above, for connecting zener barrier
Resistance bulb Pt 100, 3-wire type, 50 C span or more
Same as above, for connecting zener barrier
Slide rheostat, 3-wire type
None
Power supply
24V DC
100V AC
Common optional units
Without optional units
With time marker
With externally controlled marker
Same as above, for one-shot operation
Low/high chart speed selection
A+D
B+D
C+D
1st pen, optional units
Without optional units
Upper limit + lower limit alarm
Two upper limits alarm
Two lower limits alarm
Indication pause
K + D
2nd pen, optional units
Without optional units
Upper limit + lower limit alarm
Two upper limits alarm
Two lower limits alarm
Indication pause
K + D
3rd pen, optional units
Without optional units
Upper limit + lower limit alarm
Two upper limits alarm
Two lower limits alarm
Indication pause
K + D
Entries of input codes (
(*5)
Pen No, 1, pen No.2, pen No.3
1-pen
2-pen
3-pen
T: 150 C
Unusable for thermocouple input
Unusable for thermocouple input
Unusable for thermocouple input
5th digit
to be filled with input code) (*6)
Description
(*3)
(*3)
(*3)
6th digit
Y
(4) Linearizer is to be provided for direct inputs from thermo-
(5) When all three pens are recorded thermocouple inputs and
(6) Example of instrument code specifications:
(7) JPt 100…JIS C 1604-1981
• Asterisked (*) items; Nonstandard.
(*1) (*2)
couple and resistance bulb.
are equipped with alarm devices, E, F or G cannot be
specified in 10th digit (due to number of terminals).
Pt100…IEC Pub 751-1983
7th digit
Y
Y
PFA2ABY1-1YKYY
(*7)

Related parts for EDS10-15F