EDS10-17E FUJI [Fuji Electric], EDS10-17E Datasheet - Page 2

no-image

EDS10-17E

Manufacturer Part Number
EDS10-17E
Description
FC SERIES ELECTRONIC INTEGRATOR
Manufacturer
FUJI [Fuji Electric]
Datasheet
2
Ambient humidity:
Outline dimensions (HxWxD):
Mass (weight): Approx. 4.5kg
Finish color:
Mounting method:
Optional Functions
Protection against power interruption:
Pulse transmission (provided only with analog input):
Relay contact (not possible when power failure protection
provided)
PKH
Contact make time; 80 to 200 msec
Kinds of pulses
No-contact pulse (semiconductor contact output)
Contact capacity;
Withstand voltage, 500V AC for 1 minute between
Output contact;
Contact capacity;
Withstand voltage; 1000V AC for 1 minute between
When power is interrupted (including when power switch
is OFF), functions such as integration, indication, pulse
transmission and BCD transmission are stopped. When
power is restored, integration resumes from the value
held when the power interruption occurred. This is be-
cause a battery serves as a memory backup for retaining
the memory contents (integrated value). The battery is
effective for about 170 hours or about 7 days (power inter-
ruption time).
Pulses corresponding to the integration constant x 1, x 2,
Output contact, NPN transistor open collector
x 5 or x 10 are transmitted outside. Integration constant
x 1/2, x 1/5, or x 1/10 is also available.
90%RH or less
144 x 72 x 400mm(case) + terminal section
Munsell 7Y 7.3/1.4; frame color of N1.5
is available on request
Panel flash-mount type
33V DC, 50mA max.
100V AC, 0.3A / 24V DC, 02A
5V DC, 1mA min.
33V DC between PO+ and PO-
NO contact
PO- and ground
contacts and ground
(resistive load)
= 90 to 0
33
P0+
P0-
Parallel connection for BCD transmission (negative logic):
Integrated value transmission:
Integrated value is transmitted outside in BCD code. A
signal which can be read out is simultaneously transmit-
ted. When ENABLE signal of "L" level from outside is
input, the value in the output register is held and there is
no change in the output. When the internal data are
undergoing change, a BUSY signal is transmitted (does
not affect the ENABLE signal).
Kinds of signals
Kinds of DATA outputs (one kind should be specified)
The BCD outputs of multiple integrators can be connected
in parallel and changed over and measured via an external
device.
DATA, BUSY
Integrator
COM
o DATA;
o BUSY;
o ENABLE;
o COM;
o RESET;
o Transistor output negative logic
o Transistor output positive logic
(output is "L" level when internal data "H")
(output is "H" level when internal data "H")
Integrator
(Caution is necessary at the external device when
using RESET/ENABLE, please consult with Fuji.)
BCD 6 digits, parallel output
Conversion in progress, H or L level
selectable; at high impedance when
integrator power interrupted
(transistor OFF)
Signal from outside; output value
remains unchanged when at L level
0V
Reset signal from outside; counter is
reset when at L level
DATA, BUSY
Integrator
Integrator
COM
External device
External
device
External
device