EDS6-122A FUJI [Fuji Electric], EDS6-122A Datasheet
EDS6-122A
Related parts for EDS6-122A
EDS6-122A Summary of contents
Page 1
... Rated values DC, 20 mA. ON voltage less. 5-core shielded cable (1 m) ... For externally energized type 12 to 45V DC Direct sunshine is not permissible. Parameter settings and total value are held in EEPROM FMR, M (Note kg (normal), m (normal)], and EDS6-122a Date Aug. 10, 2005 ...
Page 2
FMR, M CODE SYMBOLS Description Note FMR Digit 4 <Nominal diameter> 5 10mm 0 6 15mm 0 25mm 0 40mm 0 50mm 0 80mm 0 100mm 1 7 <Connecting flange standard> JIS 10k JIS 16k ...
Page 3
FLOW RATE RANGE [Table1] ¡Liquid Retain the minimum flow rate in Tables A (according to specific gravity) and B (according to viscosity), whichever is the greater. Table A (according to specific gravity) Minimum flow rate Nominal 0.5 0.6 0.7 0.8 ...
Page 4
FMR, M ¡Saturated vapor Pressure 15mm MPa (gauge) Minimum Maximum Minimum Maximum Minimum Maximum Minimum Maximum Minimum Maximum Minimum Maximum 0.049 5 0.098 6 0.196 8 0.294 9 0.392 ...
Page 5
Correct pulse unit for fixed conversion Use the following unit selection table for determining a correct pulse unit for fixed conversion to standard status (normal) flow rate or mass flow rate by multiplying the volu- metric flow rate by conversion ...
Page 6
FMR, M Installation procedure [Fig Length of straight pipe: Conforms to ISO 5167 No. Piping status L Flow Fuji’s Honey vane L 1 regulating L pipe Flow Flow straightener L 2 Reducer Flow L Flow L Elbow 3 ...
Page 7
OUTLINE DIAGRAM (Unit: mm) For liquid and gas (80 C max.) Nominal d (mm) L (mm) I (mm) diameter (mm 32 32.5 14 32 48.5 ...
Page 8
FMR, M OUTLINE DIAGRAM (Unit: mm) For high temperature (200 C max.) of liquid, gas and vapor Nominal L (mm) I (mm) d (mm) diameter (mm 32 32.5 14 32.5 26 ...
Page 9
INTEGRATING METER (Type: FMM) OVERVIEW This instrument is a compact type LCD display counter that receives pulse signal from vortex flowmeter and indicates total flow and digital instantaneous flow rate (with power supply for the oscillator built in). FEATURES 1. ...
Page 10
FMR, M CODE SYMBOLS Digit Description 4 <Power voltage> 264V AC 50/60Hz 5 Input signal 3-wire open corrector pulse 6 Output signal (open collector) Pulse width: Approx. 1ms Pulse width: Approx. 50ms Pulse Width: Approx. 100ms Pulse width: ...
Page 11
OUTLINE DIAGRAM (Unit: mm) (Wall type) CONNECTIONS Terminal Display Category No. 1 SUP. Flow rate FLOW 2 SIG. input INPUT 3 0V Lower 4 + terminals PULSE Pulse OUT output (+) POWER Power 7 L2 (-) ...
Page 12
FMR, M For enquiry, show us the following specifications. Fill out the required portions or make check marks in the squares. Setting item 1. Measured fluid 1 2. Range of flow rate * Max. * Analog full scale corresponds to ...