EDS11-103E FUJI [Fuji Electric], EDS11-103E Datasheet - Page 3

no-image

EDS11-103E

Manufacturer Part Number
EDS11-103E
Description
FC SERIES MANUAL LOADER(CONTINUOUS OUTPUT TYPE)
Manufacturer
FUJI [Fuji Electric]
Datasheet
6. Transmission functions
(1) Transmission items
Setting operation items:
(2) Transmission setting inhibit:
(3) Communication interface
(a) T-link: Private interface
(b) RS-422A/485: Universal interface
(c) CC data line: Private interface
7. Other functions
Data protective function by use of pass code
8. Additional functions (options)
(1) Hard manual unit (HMV)
Control output: 4 to 20mA DC
Allowable load resistance:
9. Operating conditions
Power supply:
Power consumption:
Dielectric strength:
Insulation resistance:
Ambient temperature:
Ambient humidity:
Enclosure:
Rating plate (Name plate):
Dimensions:
Mass {weight}:
Supervisory items:
Parameter setting enable/inhibit can be designated by
transmission from the host. Designation is done by keys
on the front panel.
Transmission speed: 500Kbps
No. of units connectable: 32 max.
Transmission distance: 1km max.
Transmission form: Multi-drop
Control method: I/O transmission and message
Transmission speed: 2400, 4800, 9600 or 19200bps
No. of units connectable: 31 max.
Transmission distance: 1km max.
Transmission form: Multi-drop
Control method: Polling/selecting
Transmission speed: 19.2Kbps
No. of units connectable: 15 max.
Transmission distance: 500m max.
Transmission form: Multi-drop
Control method: Polling/selecting
PNB
Process value, control output, operation
mode, alarm information, fault informa-
tion, various limiter values, constants, etc.
Host
Control output, operation mode, various
limiter values, constants, etc.
600
Selected from the following 3 types
24V DC (20 to 30V DC)
100V AC (85 to 132V/47 to 63Hz AC)
200V AC (187 to 264V/47 to 63Hz AC)
Approx. 11W (DC)
Approx. 20VA (AC)
1500V AC, 1 min.
100M
0 to 50 C
90% RH or less
Steel case
100 (H) x 72 (W) mm, white acryl
144 (H) x 72 (W) x 391 (D) mm, IEC
(DIN) standards
Approx. 2.9kg
or less (24V DC power only)
configurable
host
PNB
or more at 500V DC
Mounting method:
Finish color:
Scope of delivery: Manual loader and mounting bracket
Item to be ordered separately:
CODE SYMBOLS
P N B 1
1 2 3 4 5 6 7 8
W
D
G
A
B
C
E
F
A
B
1
2
3
5 -
1
2
9 10
Notes: Symbols of resistance bulbs are as follows.
Flush with indoor panel; vertical mounting
is standard.
Mounting on tilted surface possible (angle
" ")
Munsell N 1.5 for front panel and case
Communication cable (type PNZ)
Y
R
S
C
T
Process value input signal
1 to 5V DC
4 to 20mA DC
J thermocouple
K thermocouple
E thermocouple
R thermocouple
Resistance bulb, JPt 100, 3-wire, 50 C
span or more
Resitance bulb, Pt100, 3-wire, 50 C
span or more
Operating method
M type
A-M type
Power supply
24V DC (20 to 30V DC)
100V AC (85 to 132V/47 to 63Hz AC)
200V AC (187 to 264V/47 to 63Hz AC)
Hard manual back-up unit
(24V DC power only)
None
With
Transmission function
None
T-link
RS-422A
RS-485
CC data line
JPt100.....JIS C 1604-1981
Pt100.....IEC Pub 751-1983
(Selection of JPt100/Pt100 is possible by
using front panel key.)
=0 to 90
Description
10mV DC span or
more, cold junction
compensation
comprised
3