EDS11-109E FUJI [Fuji Electric], EDS11-109E Datasheet - Page 2

no-image

EDS11-109E

Manufacturer Part Number
EDS11-109E
Description
MICRO CONTROLLER "H"
Manufacturer
FUJI [Fuji Electric]
Datasheet
2
2. Table of input/output specifications and alarm
Input (measured value)
Control
output 1
Control
output 2
(dual control
type only)
Auxiliary
Main alarm output
Heater break alarm output
Fault output
3. Setting and indication
(1) Accuracy:
(2) Remote setting input accuracy:
(3) Setting method:
(4) Indicating method:
4. Power failure backup
5. Status function
6. Digital communication function
P Y H
PV/SV/MV
transmis-
sion output
Auxiliary
alarm
output
output
Set point values and PID parameters are stored in non-
volatile memory for automatic re-start
Self-diagnosis using watchdog timer
Universal interface:
Item
Relay contact
Current
SSR/SSC drive
Motor-driven
value operation
Relay contact
Current
SSR/SSC drive
Analog
Valve position
Digital 1
Digital 2
Digital 3
Analog
Digital 1
Digital 2
Digital 3
Temperature compensation: 1 C
Key switch
7-segment LED, 4 digits
cation (LED lamp)
PS-485: Used for PYH5 and PYH9 as an
0.2% FS, 1 digit
0.2% FS
option.
...................................................................................................................................................................................
Thermocouple, resistance bulb, voltage,
current
With transmitter power supply DC 4 to
20mA (PYH9 only)
mV input: leak current: 3 A
AC 220V, 3A (resistive load), 1c contact
DC 4 to 20mA, load resistance 600
DC 10 to 27V at ON, 0.5V DC or less at OFF,
max. current DC 20mA.
AC 200V, 3A (resistive load), 1a contact
AC 220V, 3A (resistive load), 1c contact
DC 4 to 20mA, load resistance 600
DC 10 to 27V at ON, DC 0.5V or less at OFF,
max. current DC 20mA.
DC 1 to 5V, input resistance 1M
100 to 1000 , 3-wire potentiometer
Contact, DC 24V, 15mA (R-ACK or SV selec-
tion
Ditto (EX-MV command)
Ditto (PYH9 only) (CAS-SV)
DC 1 to 5V, input impedance of connected
device 500k
DC 30V, 0.1A, 1a contact (PYH5: opencollector,
DC 30V, 0.1A)
Ditto (PYH9 only)
Ditto (PYH9 only)
AC 220V, 1A, 1a contact
AC 220V, 1A, 1a contact (PYH5: opencollector,
DC 30V, 0.1A)
DC 30V, 0.1A, 1a contact
or more
Rating
2, mode indi-
2
or more
or less
or less
2
7. Operation mode
8. Alarm functions
(1) Main alarm: Absolute value upper/lower limit, devia-
(2) Heater break alarm:
(3) Auxiliary alarm/limiter:
Remote mode operation, auto mode operation, manual
mode operation
Point control
(PYH5, 9)
Fixed set
type
Inverter con- Position feed- Dual control
(PYH9 only)
trol type
tion upper/lower limit, absolute value
lower limit with lower limit hold, devia-
tion lower limit with lower limit hold, de-
viation upper/lower limit with lower limit
hold, deviation upper/lower limit.
Alarm output with connection to sepa-
rate-ly installed current transformer (CT).
Measured value upper/lower limit, mani-
pulated output upper/lower limit, set
point value upper/lower limiter, manipu-
lated output upper limiter
Type
back control
(PYH5, 9)
type
(PYH5, 9)
type