EDS11-159C FUJI [Fuji Electric], EDS11-159C Datasheet
EDS11-159C
Related parts for EDS11-159C
EDS11-159C Summary of contents
Page 1
... Withstand voltage: Power source all terminals 1500 V AC for 1 min Relay contact output 1500 V AC for 1 min Between others 500 V AC for 1 min (5) Approvals and certification: UL(UL873), C-UL(CSA C22.2 No.24-93 or equivalent), CE mark(LVD : EN61010-1, EMC : EN61326-1) PXG5 all terminals EDS11-159c Date Apr. 1, 2011 ...
Page 2
PXG5 2. Input section 2.1 Process value input (1) Number of inputs: 1 point (2) Input setting: Programmable scale (3) Input signal: See Table 1 (thermocouple, resistance bulb, mV, voltage, , current(With exter- nal 250 resistance) universal input) (4) Standard ...
Page 3
Output section 3.1 Control output (1) Number of points points (2 points: Heating/cooling control) (2) Type: selected out of [1] to [5] below [1] Relay contact output • Proportional cycle 150 sec • Contact ...
Page 4
PXG5 5. Control functions 5.1 Control types (1) 2-position control (set parameter P to 0%) (2) PID control (fuzzy PID included) • PID parameters determination: Auto tuning, Selftuning (3) PID dual (heating, cooling) function (fuzzy PID included) • PID parameters ...
Page 5
Scope of delivery • Controller: 1 unit • Instruction manual: 1 copy • Fixture: 2 pcs • Water-proof packing • Shunt resistor • Unit nameplate 13. User customize function 13.1 Program (ramp/soak) function ...
Page 6
PXG5 CODE SYMBOLS Standard type Digit Specifications 4 <Front panel size W H> 48 96mm 5 <Output 1> Relay contact SSR drive Current ( DC DC) Voltage ( DC ...
Page 7
CODE SYMBOLS Motorized valve control type Digit Specifications 4 <Front panel size W H> 48 96mm 5 <Output 1> Motorized valve control output (Without PFB) Motorized valve control output (With PFB) 6 <Output 2> None Auxiliary Digital output 7 <Option ...
Page 8
PXG5 OPTIONALLY ITEMS Instruction manual for communication functionRS485 (Modbus) Current detector for heater burnout alarm Rear terminal cover Shunt resistor 250 0.1% PC loader communication cable TABLE 1 [1] Unit of temperature: ˚C Input Input type code 0 JPt100 Resistance ...
Page 9
OUTLINE DIAGRAM (Unit : mm) 48 Water-proof packing 1-12 13-24 25- Terminal screw M3 Panel cutout ...
Page 10
PXG5 OPTIONALLY ARRANGED ARTICLES Heater current detector (CT) . Specification : Type : CTL-6-S 5 Note 1) Detection is available only for single phase heater. Note 2) Unusable for heater control ...
Page 11
EXTERNAL CONNECTION DIAGRAM Standard type with communication OPTION 1 RS485,DI1,RSV1,CT1 RS485+DI+RSV1 RS485+RSV1/RS485+CT1/RS485+ RS485 RS485 RS485 2 2 DI1 3 3 DI- RSV1 CT1 4 COM 4 5 RSV1 ...
Page 12
PXG5 Standard type without communication OPTION 1 DI1,DI2,RSV1,CT1 DI1+DI2+RSV1 DI1+RSV1/DI1+CT1/DI1+DI2 DI1 1 1 DI1 DI- DI-COM 2 2 COM DI2 3 3 RSV1 RSV1 6 Power supply PS DO DO1- COM DO1 11 11 DO2- COM 12 ...
Page 13
Motorized valve control type with communication OPTION1 RS485,DI1,DI2,DI3,RSV1 RS485+DI+RSV1 RS485+DI1+DI2+DI3 1 RS485 RS485 2 DI1 DI1 3 DI- DI- 4 COM COM DI2 5 RSV1 6 DI3 PS Power supply DO DO1- COM DO1 11 11 DO2- COM 12 12 ...
Page 14
PXG5 Motorized valve control type without communication OPTION1 DI1,DI2,DI3,RSV1 DI1+DI2+DI3+RSV1 DI1 1 DI- 2 COM DI2 3 4 DI3 5 RSV1 Power supply DO DO1,DO2,DO3 DO1- ...
Page 15
ISOLATED BLOCK DIAGRAM Power supply Control output 1 (relay contact) or OPEN output Control output 2 (relay contact) or CLOSE output Digital output 1 (relay contact) Digital output 2 (relay contact) When the 9th digit of the code symbols = ...
Page 16
PXG5 ...