FX-102-CFC-A1C2 VECTRON [Vectron International, Inc], FX-102-CFC-A1C2 Datasheet - Page 2

no-image

FX-102-CFC-A1C2

Manufacturer Part Number
FX-102-CFC-A1C2
Description
Frequency Translator
Manufacturer
VECTRON [Vectron International, Inc]
Datasheet
FX-102 Frequency Translator
kHz, 1.544 MHz, 2.048 MHz, 19.440 MHz etc. to any
specific frequency from 77.76 to 170 MHz. The input
frequency does not have to be a 50/50% duty cycle and
as an example can be an 8 kHz signal with a logic high
"on time" of only 1us, such as a BITS clock . The FX-102
also has the ability to translate any of 1 to 4 diffe r e n t
input frequencies to one
19.44 MHz and any other frequency between 8 kHz and
170 MHz translating them to any specific output fre-
Performance Characteristics
Vectron's FX-102 is a crystal based frequency tra n s l a t o r
which is used to translate any input frequency such as 8
such as input frequencies of 8 kHz and 1.544 MHz and
quency from 77.76 MHz to 170 MHz.
Description
Parameter
Output Frequencies
Supply Voltage,
Supply Current
Input Signal,
OUTPUT,
V
V
V
V
Rise/Fall Time
Output Symmetry
Jitter Generation, rms
Jitter Generation, rms
Jitter Transfer, GR-253-CORE sec 5.6.2.1.2
Input Frequency Tracking Capability
(Can translate a Stratum 1,2,3,3E,4
or SONET Min source)
Operating Temperature
Size
OH
OL
OH
OL
Vectron International • 267 Lowell Road, Hudson, NH 03051 • Tel: 1-88-VECTRON-1 • Web: www.vectron.com
(Temp Range C = 0°C to +70°C)
(Temp Range F = -40°C to +85°C)
(Temp Range C = 0°C to +70°C)
(Temp Range F = -40°C to +85°C)
(12 kHz to 20 MHz)
(cycle to cycle method)
C = 5 Vdc
D = 3.3 Vdc
A = HCMOS
D = PECL
F = Comp PECL
common output frequency,
Symbol
CLKIN
CLKIN
Sym
APR
V
V
t
V
V
V
V
R
I
---
cc
OH
OH
OL
OL
/t
cc
cc
25.4 x 20.32 x 6.35 mm (1.0” x 0.8” x 0.25”)
F
V
V
V
V
The "Input Frequency tra cking capability" is the total
amount of input frequency deviation in which the FX-102
is guaranteed to tra ck or tra n s l a t e. As an ex a m p l e, a typ-
ical input clock would be 8 kHz ±20 ppm.The FX-102 is
g u a ranteed to tra ck at least ±40 ppm of error ove r
t e m p e rature/ aging/ power supply and is more than twice
what most applications require. The PLL control vo l t a g e
is brought out through a 470K ohm resistor. This wo u l d
a l l ow for the use of ex t e rnal circuitry (analog compara-
tors or an A/D conve rter plus a processor) to detect
when the control voltage is getting close to the limits of
the pull ra n g e.
cc
cc
cc
cc
77.76
Min
4.75
3.15
±40
-1.025
-1.810
-1.085
-1.830
45
---
Temp Range C =
Temp Range F = -40°C to +85°C
Typical
HCMOS
PECL
PECL
5.00
3.30
<0.5
0.5
75
3
0°C to +70°C
V
V
V
V
cc
cc
cc
cc
Max
5.25
3.45
170
100
-0.880
-1.620
-0.880
-1.555
0.1
55
---
---
1
1
5
Unit
MHz
ppm
Vdc
Vdc
mA
dB
---
---
ns
ps
ps
%
V
V
V
V

Related parts for FX-102-CFC-A1C2