G2R-1-SD ETC [List of Unclassifed Manufacturers], G2R-1-SD Datasheet - Page 3

no-image

G2R-1-SD

Manufacturer Part Number
G2R-1-SD
Description
General-purpose Relay
Manufacturer
ETC [List of Unclassifed Manufacturers]
Datasheet
G2RS
Plug-in Terminal Relays
Note: 1. P level:
Standard Relays
Note: Values in the above table are the initial values.
4
Number of poles
Load
Rated load
Rated carry current
Max. operating voltage
Max. operating current
Max. switching
capacity
Min. permissible load
Contact resistance
Operate (set) time
Release (reset) time
Max. operating frequency
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Life expectancy
Ambient temperature
Ambient humidity
Weight
Contact Ratings
Characteristics
2. ( ): Twin crossbar contact type.
*2,000 VAC, 50/60 Hz for 1 minute when the P2R-05A or P2R-08A socket is mounted.
Item
60
= 0.1 x 10
1 pole
Resistive load
(cos = 1)
10 (1) A at 250 VAC;
10 (1) A at 30 VDC
10 (1) A
380 VAC, 125 VDC
10 (1) A
2,500 (250) VA,
300 (30) W
100 mA at 5 VDC (1 mA at 5 VDC)
-6
/operation
30 m max.
15 ms max.
AC: 10 ms max.; DC: 5 ms max. (w/built-in diode: 20 ms max.)
Mechanical: 18,000 operations/hr
Electrical:
1,000 M min. (at 500 VDC)
5,000 VAC, 50/60 Hz for 1 min between coil and
contacts*;
1,000 VAC, 50/60 Hz for 1 min between contacts
of same polarity
Destruction: 10 to 55 Hz, 1.5-mm double amplitude
Malfunction: 10 to 55 Hz, 1.5-mm double amplitude
Destruction: 1,000 m/s
Malfunction: 200 m/s
Mechanical: AC coil: 10,000,000 operations min.;
Electrical:
Operating: –40 C to 70 C (with no icing)
Storage:
Operating: 35% to 85%
Storage:
Approx. 17 g (plug-in terminal: approx. 20 g)
–40 C to 70 C (with no icing)
35% to 85%
DC coil: 20,000,000 operations min. (at 18,000 operations/hr)
100,000 operations min. (at 1,800 operations/hr under rated load)
1,800 operations/hr (under rated load)
Inductive load
(cos = 0.4; L/R = 7 ms)
7.5 A at 250 VAC;
5 A at 30 VDC
1,875 VA,
150 W
1 pole
2
when energized (approx. 20G); 100 m/s
2
(approx. 100G)
2 poles
Resistive load
(cos = 1)
5 A at 250 VAC;
5 A at 30 VDC
5 A
380 VAC, 125 VDC
5 A
1,250 VA,
150 W
10 mA at 5 VDC
50 m max.
5,000 VAC, 50/60 Hz for 1 min between coil and
contacts*;
3,000 VAC, 50/60 Hz for 1 min between
contacts of different polarity
1,000 VAC, 50/60 Hz for 1 min between
contacts of same polarity
2
when no energized (approx. 10G)
2 poles
Inductive load
(cos = 0.4; L/R = 7 ms)
2 A at 250 VAC; 3 A at
30 VDC
500 VA,
90 W
G2RS