7001309-J100 Emerson Network Power, 7001309-J100 Datasheet
7001309-J100
Related parts for 7001309-J100
7001309-J100 Summary of contents
Page 1
MicroTCA MTC600 Series 600 Watts Total Power: 600 Watts # of Channels: 16 Special Features • 600 W output power • 16 Channels of • 7.6 A max • 3 150 mA max • Supports: ...
Page 2
Product Description (continued) Input Power Module Power Module Input Connector Input Connector - 48V_A - 48V_A Fusing Fusing ORing ORing EMI Filtering EMI Filtering EMI Filtering Transient Suppression Transient Suppression Transient Suppression Inrush Limiting Inrush Limiting Inrush Limiting Holdup Holdup ...
Page 3
Electrical Specifications Input -48 Vdc Models Input Range (Operating) Input Range (Non-operating) Input Fusing Input ORing Inrush Current Input Current Holdup Time UnderVoltage Lockout Reverse Polarity Protection AC Models Input Range (Operating) Input Range (Non-operating) Frequency Input Fusing Inrush Current ...
Page 4
Electrical Specifications (continued) Output - All Models (continued) 1 Outputs (Payload Power) Management Power Interdependence Setpoint Total Regulation Range Rated Load Minimum Load Output Rise TIme (per channel) 3 Output Noise (PARD) Output Voltage Overshoot Transient Response Voltage ...
Page 5
Electrical Specifications (continued) Output - All Models (continued) 5,6 3.3 V Outputs (Management Power) Payload Power Interdependence Setpoint Total Regulation Range Rated Load Minimum Load Output Rise TIme (per channel) 3 Output Noise (PARD) Output Voltage Overshoot Transient Response Voltage ...
Page 6
Electrical Specifications (continued) Output - All Models (continued) General Turn-on Time Early Power Normal Power Autonomous Operation Diagnostic Mode 7 Redundancy Hot-Swap Operation (controlled) Hot-Swap Operation (uncontrolled) Power Module Failover Fault Isolation Note 7: All specifi cations in the redundancy ...
Page 7
Electrical Specifications (continued) Input Signals - All models Geographic Address: GA0, GA1, GA2 Internal pull ups to 3.3 V. Source current limited by 11 Kohm (300 μA with GAx at 0.0 V) Logic Level Low - V IL Logic Level ...
Page 8
Electrical Specifications (continued) Output Signals - All Models EN1_[SLOT]#: EN1_M1, EN1_M2, EN1_CU1, EN1_CU2, EN1_1, EN1_2...EN1_12 Open collector output. Isink, max=10 mA. No internal current limit Logic Level Low Voltage - V OL Voltage Withstand - V max PM_OK#: PM_OK# Open ...
Page 9
Electrical Specifications (continued Interface - All Models Operating Parameters Operating Voltage Operating Frequency SDA_[x]: SDA_A, SDA_B Internal pull ups to 3.3 V. Source current limited by 10 Kohm (330 μA with ...
Page 10
IPMB-0 Interface PM-EMMC Functionality A PM-EMMC is implemented per MicroTCA.0 R1.0 requirements 4.116 through 4.120 IPM Device IPMB Interface SDR Repository Sensors Watchdog Timer FRU Inventory Initialization Agent Internal Event Generation External Event Generation Power Channel Mapping Power Channel Management ...
Page 11
IPMB-0 Interface (continued) Supported Commands (Continued) Sensor Device Commands NetFN S/E Request=04h; Response=05h Command Get Device SDR Info Get Device SDR Reserve Device SDR Repository Set Sensor Hysteresis Get Sensor Hysteresis Set Sensor Threshold Get Sensor Threshold Get Sensor Reading ...
Page 12
IPMB-0 Interface (continued) Sensors - Mandatory per PICMG and Related Standards Event and Status Sensors These sensors are implemented according to the requirements and specifications of the relevant standards. Sensor Name Management Controller Device Locator Power Channel Notification PM Status ...
Page 13
IPMB-0 Interface (continued) Sensors - Non-Mandatory per PICMG and Related Standards (continued) Input Voltage Sensors All voltage sensors have an accuracy of 2%. Sensor Name AC Input Voltage DC Input Votlage A DC Input Voltage B DC Input Or-ed Thresholds ...
Page 14
Environmental Specifications Temperature and Altitude Derating 60 m below to 1800 m above sea level Condition Storage Non-Operating Cold Start Normal Operation 9 Short Term Operation 1800 m to 4000 m above sea level Condition Storage Non-Operating Cold Start Normal ...
Page 15
Electromagnetic Compatibility All Models Radiated Emissions Standard EN55022, Class A Per Section 6 GR-1089-CORE Per Section 3.2 Conducted Emissions EN55022, Class A Per Section 6 GR-1089-CORE Per Section 3.2 ElectroStatic Discharge EN61000-4 Contact Air discharge Radiated ...
Page 16
Mechanical Specifications (continued) Front Panel - MTC600-48 Input Connector: Positronics QB7W2MN7T2, FCI 10070158, or equivalent Mating Connector: Positronics QB7W2F00QH0/AA, FCI 10070165, or equivalent Pinout: P1: Return P2: - Not Used 2: Not Used Front Panel Drawing for DC-input ...
Page 17
Mechanical Specifications (continued) Output Connector Output Connector: EPT P/N 501-50096-183, Tyco P/N 1469922-1, or equivalent Mating Connector: EPT P/N 502-50096-183, Tyco P/N 1469920-1, or equivalent Pinout P1 PP_M1(2nd Mate) PP_1(2nd Mate) P2 PP_CU1(2nd Mate) PP_2(2nd Mate) P3 PP_CU2(2nd Mate) PP_3(2nd ...
Page 18
Mechanical Specifications MTC600-48 0.18 (4.55) 0.63 (16) 15.24 (0.6) 15.24 (0.6) MTC600-AC 2.34 (59.40) 2.89 (73.5) Embedded Power for Business-Critical Continuity 7.37 (187.25) 7.37 (187.25) Rev. 05.26.08 MTC600 Series ...
Page 19
... DC Power Embedded Power Inbound Power Integrated Cabinet Solutions Outside Plant Precision Cooling Site Monitoring and Services EmersonNetworkPower. com Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. ©2006 Emerson Electric Co. Rev. 05.26.08 MTC600 Series ...