GN (AGN)
3) High sensitivity single side stable type
*Pulse drive (JIS C 5442-1996)
2. Specifications
Notes: *1 This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
REFERENCE DATA
1. Max. switching capacity
Contact
Rating
Electrical
characteristics
Mechanical
characteristics
Expected life
Conditions
Unit weight
Nominal coil
Characteristics
1.5V DC
4.5V DC
12V DC
24V DC
voltage
3V DC
6V DC
9V DC
*2 Refer to 6. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT (Page 24).
1.0
0.3
actual load.
nominal voltage*
80%V or less of
(at 20°C 68°F)
Arrangement
Initial contact resistance, max.
Contact material
Nominal switching capacity
Max. switching power
Max. switching voltage
Max. switching current
Min. switching capacity (Reference value)*
Nominal operating
power
Insulation resistance (Initial)
Breakdown voltage
(Initial)
Surge breakdown
voltage (Initial)
Temperature rise (at 20°C 68°F)
Operate time [Set time] (at 20°C 68°F)
Release time [Reset time] (at 20°C 68°F)
Shock resistance
Vibration resistance
Mechanical
Electrical
Conditions for operation, transport and storage*
Max. operating speed (at rated load)
30
Set voltage
(Initial)
Contact voltage, V
DC resistive load
AC resistive load
100
Single side stable
High sensitivity single side
stable type
1 coil latching
Between open contacts
Between contact and coil
Between contact sets
Between open contacts
Between contacts and coil
Functional
Destructive
Functional
Destructive
10%V or more of
nominal voltage*
Item
(at 20°C 68°F)
Reset voltage
(Initial)
2. Life curve
1
100
50
40
30
20
10
0
[±10%] (at 20°C 68°F)
2
Nominal operating
0.2
66.7mA
33.3mA
22.2mA
16.7mA
11.1mA
current
8.3mA
5.0mA
2 Form C
Max. 100 mΩ (By voltage drop 6 V DC 1A)
Stationary contact: AgPd+Au clad Movable contact: AgPd
1 A 30 V DC, 0.3 A 125 V AC (resistive load)
30 W (DC), 37.5 V A (AC) (resistive load)
110 V DC, 125 V AC
1 A
10µA 10 mV DC
140mW (1.5 to 12 V DC), 230mW (24 V DC)
100mW (1.5 to 12 V DC), 120mW (24 V DC)
Min. 1,000MΩ (at 500V DC)
Measurement at same location as “Initial breakdown voltage” section.
750 Vrms for 1min. (Detection current: 10mA)
1,500 Vrms for 1min. (Detection current: 10mA)
1,000 Vrms for 1min. (Detection current: 10mA)
1,500 V (10×160µs) (FCC Part 68)
2,500 V (2×10µs) (Telcordia)
Max. 50°C
(By resistive method, nominal coil voltage applied to the coil; contact carrying current: 1A.)
Max. 4 ms [Max. 4 ms] (Nominal coil voltage applied to the coil, excluding contact bounce
time.)
Max. 4 ms [Max. 4 ms] (Nominal coil voltage applied to the coil, excluding contact bounce
time.) (without diode)
Min. 750 m/s
Min. 1,000 m/s
10 to 55 Hz at double amplitude of 3.3 mm (Detection time: 10µs.)
10 to 55 Hz at double amplitude of 5 mm
Min. 5 × 10
Min. 10
Ambient temperature:
(Single side stable, 1 coil latching type) –40°C to +85°C
(High sensitivity single side stable type) –40°C to +70°C
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
20 cpm
Approx. 1 g
0.4
AC 125V
resistive load
Switching current, A
5
(1 A 30 V DC resistive), 10
0.6
DC 30V resistive load
7
.035 oz
(at 180 cpm)
2
(Half-wave pulse of sine wave: 6 ms; detection time: 10µs.)
2
0.8
(Half-wave pulse of sine wave: 6 ms.)
[±10%] (at 20°C 68°F)
Coil resistance
1.0
202.5Ω
1,440Ω
4,800Ω
22.5Ω
360Ω
810Ω
90Ω
1.2
5
(0.3 A 125 V AC resistive) (at 20 cpm)
Specifications
3. Mechanical life
Tested sample: AGN2004H, 15 pcs.
Operating speed: 180 cpm
Nominal operating
3.5
2.5
1.5
0.5
4
3
2
1
0
0
100mW
120mW
power
–40°F to +185°F
–40°F to +158°F
Drop-out voltage
10
Pick-up voltage
No. of operations, ×10
Max. applied voltage
ASCTB13E 201111-T
nominal voltage
nominal voltage
(at 20°C 68°F)
30
150%V of
120%V of
4
50
Max.
Min.
Max.
Min.

Related parts for AGN20012J01