IDTQS3390SOG IDT, Integrated Device Technology Inc, IDTQS3390SOG Datasheet - Page 4

MUX 16:8 SH QUICKSWITCH 28-SOIC

IDTQS3390SOG

Manufacturer Part Number
IDTQS3390SOG
Description
MUX 16:8 SH QUICKSWITCH 28-SOIC
Manufacturer
IDT, Integrated Device Technology Inc
Type
Multiplexerr
Datasheet

Specifications of IDTQS3390SOG

Circuit
1 x 16:8
Independent Circuits
1
Voltage Supply Source
Single Supply
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
28-SOIC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Voltage - Supply
-
Current - Output High, Low
-
Other names
800-1741
800-1741-5
800-1741
QS3390SOG
NOTES:
1. For conditions shown as Min. or Max., use the appropriate values specified under DC Electrical Characteristics.
2. Per TTL-driven input (V
3. This current applies to the control inputs only and represents the current required to switch internal capacitance at the specified frequency. The A, B, and AB inputs generate
POWER SUPPLY CHARACTERISTICS
SWITCHING CHARACTERISTICS OVER OPERATING RANGE
T
C
NOTES:
1. Minimums are guaranteed but not production tested.
2. This parameter is guaranteed but not production tested.
3. The bus switch contributes no propagation delay other than the RC delay of the ON resistance of the switch and the load capacitance. The time constant for the switch alone
IDTQS3390
HIGH-SPEED CMOS QUICKSWITCH 16:8 MULTIPLEXER
A
LOAD
Symbol
Symbol
= -40°C to +85°C, V
no significant AC or DC currents as they transition. This parameter is guaranteed but not production tested.
is of the order of 0.25ns at C
system. Propagation delay of the bus switch, when used in a system, is determined by the driving circuit on the driving side of the switch and its interaction with the load on
the driven side.
ΔI
I
I
t
t
t
t
t
t
CCQ
CCD
PZH
PHZ
PLH
PHL
PZL
PLZ
CC
= 50pF, R
Quiescent Power Supply Current
Power Supply Current per Input HIGH
Dynamic Power Supply Current per MHz
LOAD
Parameter
Data Propagation Delay
A, B, to/from AB
Switch Turn-On Delay
AEN, BEN to A, B, AB
Switch Turn-Off Delay
AEN, BEN to A, B, AB
= 500Ω unless otherwise noted.
IN
CC
Parameter
= 3.4V, control inputs only). A, B, and AB pins do not contribute to ΔIcc.
= 5V ± 5%
L
= 50pF. Since this time constant is much smaller than the rise and fall times of typical driving signals, it adds very little propagation delay to the
(2)
(2)
(2)
(3)
V
V
V
@ 50% Duty Cycle
CC
CC
CC
= Max., V
= Max., V
= Max., A, B, and AB Pins Open, Control Inputs Toggling
Test Conditions
IN
IN
= GND or V
= 3.4V, f = 0
4
Min
CC
1.5
1.5
(1)
.
, f = 0
(1)
Typ.
INDUSTRIAL TEMPERATURE RANGE
0.25
Max.
6.5
5.5
(3)
Max.
0.25
1.5
3
mA/MHz
Unit
Unit