MAX1464CAI+ Maxim Integrated, MAX1464CAI+ Datasheet - Page 28

no-image

MAX1464CAI+

Manufacturer Part Number
MAX1464CAI+
Description
Digital Signal Processors & Controllers - DSP, DSC Low-Power Low-Noise Multichannel Sensor Signal Processor
Manufacturer
Maxim Integrated
Series
MAX1464r
Datasheet

Specifications of MAX1464CAI+

Data Bus Width
16 bit
Program Memory Size
4 KB, 128 B
Maximum Clock Frequency
5.3 MHz
Number Of Programmable I/os
2
Operating Supply Voltage
5 V
Interface Type
SPI
On-chip Adc
Yes
Processor Series
MAX1464
Product
DSPs
Program Memory Type
Flash
Low-Power, Low-Noise Multichannel
Sensor Signal Processor
Table 2. CPU Ports
28
ADDRESS
0h–Ch
______________________________________________________________________________________
Dh
Eh
Fh
P0–PC
REF
PD
PE
PF
General-Purpose Ports. These ports, P0–PC, can be used to hold intermediate calculation results,
often-used calculation coefficients, loop counter values, event counter values, comparison limit
values, etc.
Module Data Port. This port is used to transfer data to and from the various functional modules in the
MAX1464. Data loaded into PD can be transferred to the data, configuration, or control register of any
of the functional modules. The data transfer is initiated using the module control port (PF). The
contents of PD are not changed during module write operations, but are overwritten by module read
operations.
Module Address Port. This port is used to address a module register. A module address is loaded
into PE prior to initiating a data transfer or control function in the module control port. All modules in
the MAX1464 are accessed through this indirect addressing method. The contents of PE are not
changed by the read or write operations to module registers. Only the lower 8 bits are used. The
upper 8 bits are not decoded.
Module Control Port. This port initiates an operation on the module addressed by PE. Data can be
written to, or read from, module registers. Specific bits are assigned in the module control port to
initiate operations on the MAX1464 modules:
Bit 15 (CTRL): 1 = Initiate action defined in bit 14, 0 = no action initiated. Autoreset to zero after
Bit 14 (RD/WR): 1 = read data, 0 = write data.
Bits 13–0: Not decoded.
operation is completed.
FUNCTION

Related parts for MAX1464CAI+