MAX1028BEEP Maxim Integrated, MAX1028BEEP Datasheet - Page 18

no-image

MAX1028BEEP

Manufacturer Part Number
MAX1028BEEP
Description
Analog to Digital Converters - ADC
Manufacturer
Maxim Integrated
Datasheet

Specifications of MAX1028BEEP

Number Of Channels
12/6
Architecture
SAR
Conversion Rate
300 KSPs
Resolution
10 bit
Input Type
Single-Ended/Differential
Snr
Yes
Interface Type
3-Wire (SPI, Microwire), QSPI
Operating Supply Voltage
5 V
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
Package / Case
QSOP-20
Maximum Power Dissipation
727 mW
Minimum Operating Temperature
- 40 C
Number Of Converters
1
Voltage Reference
Internal 4.096 V or External

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MAX1028BEEP
Manufacturer:
MAXIM/美信
Quantity:
20 000
Company:
Part Number:
MAX1028BEEP+T
Quantity:
2 000
10-Bit 300ksps ADCs with FIFO,
Temp Sensor, Internal Reference
In clock mode 10, the wake-up, acquisition, conversion,
and shutdown sequences are initiated by writing an
input data byte to the conversion register, and are per-
formed automatically using the internal oscillator. This
is the default clock mode upon power-up. See Figure 6
for clock mode 10 timing.
Figure 5. Clock Mode 01
18
Figure 6. Clock Mode 10
CNVST
SCLK
DOUT
EOC
DIN
SCLK
DOUT
EOC
CS
CS
______________________________________________________________________________________
(ACQUISITION1)
Conversions Using the Serial Interface
THE CONVERSION BYTE BEGINS THE ACQUISITION. CNVST IS NOT REQUIRED. X = DON'T CARE.
REQUEST MULTIPLE CONVERSIONS BY SETTING CNVST LOW FOR EACH CONVERSION. X = DON'T CARE.
(CONVERSION1)
Performing Conversions in Clock Mode 10
Internally Timed Acquisitions and
(ACQUISITION2)
(CONVERSION BYTE)
(CONVERSION2)
(UP TO 514 INTERNALLY CLOCKED ACQUISITIONS AND CONVERSIONS)
MSB1
MSB1
Initiate a scan by writing a byte to the conversion regis-
ter. The MAX1026/MAX1028/MAX1030 then power up,
scan all requested channels, store the results in the
FIFO, and shut down. After the scan is complete, EOC
is pulled low and the results are available in the FIFO. If
a temperature measurement is requested, the tempera-
ture result precedes all other FIFO results. EOC stays
low until CS is pulled low again.
LSB1
LSB1
MSB2
MSB2

Related parts for MAX1028BEEP