MAX5590AEUG+ Maxim Integrated, MAX5590AEUG+ Datasheet - Page 23

no-image

MAX5590AEUG+

Manufacturer Part Number
MAX5590AEUG+
Description
Digital to Analog Converters - DAC 256-Tap Digi Pot
Manufacturer
Maxim Integrated
Datasheet

Specifications of MAX5590AEUG+

Rohs
yes
Number Of Converters
8
Resolution
12 bit
Interface Type
QSPI, SPI, Serial (3-Wire, Microwire)
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
Package / Case
TSSOP-24
Minimum Operating Temperature
- 40 C
Supply Voltage - Max
5.25 V
Supply Voltage - Min
2.7 V
DAC Programming Examples:
To load input register A from the shift register, leaving
DAC register A unchanged (DAC output unchanged),
use the command in Table 3.
The MAX5590–MAX5595 can load all of the input regis-
ters (A–H) simultaneously from the shift register, leaving
the DAC registers unchanged (DAC output unchanged),
by using the command in Table 4.
To load all of the input registers (A–H) and all of the DAC
registers (A–H) simultaneously, use the command in
Table 5.
For the 10-bit and 8-bit versions, set sub-bits = 0 for
best performance.
Table 3. Load Input Register A from Shift Register
Table 4. Load Input Registers (A–H) from Shift Register
Table 5. Load Input Registers (A–H) and DAC Registers (A–H) from Shift Register
Table 6. Select Bits (M_)
X = Don’t care.
Table 7. Select Bits Programming Example
X = Don’t care.
DATA
DATA
DATA
DATA
DATA
DIN
DIN
DIN
DIN
DIN
1
1
1
1
0
CONTROL BITS
CONTROL BITS
CONTROL BITS
Buffered, Fast-Settling, Octal, 12/10/8-Bit,
0
0
0
0
0
______________________________________________________________________________________
0
1
0
0
0
CONTROL BITS
CONTROL BITS
1
0
0
0
0
D11
D11
D11
X
X
D10
D10
D10
X
X
D9
D9
D9
X
0
D8
D8
D8
X
0
The select bits allow synchronous updating of any com-
bination of channels. The select bits command the
loading of the DAC register from the input register of
each channel. Set the select bit M_ = 1 to load the DAC
register “_” with data from the input register “_”, where
“_” is replaced with A, B, or C and so on through H,
depending on the selected channel. Setting the select
bit M_ = 0 results in no action for that channel (Table 6).
Select Bits Programming Example:
To load DAC register B from input register B while
keeping other channels (A, C–H) unchanged, set MB =
1 and M_ = 0 (Table 7).
MH
D7
D7
D7
0
Voltage-Output DACs
DATA BITS
DATA BITS
MG
DATA BITS
D6
D6
D6
0
D5
D5
MF
D5
0
Programming Commands
DATA BITS
DATA BITS
ME
D4
D4
D4
0
D3/0
D3/0
D3/0
MD
0
Advanced-Feature
D2/0
D2/0
D2/0
MC
0
Select Bits (M_)
D1/0
D1/0
D1/0
MB
1
D0/0
D0/0
D0/0
MA
0
23