SST85LP1004A-M-C-LBTE Greenliant, SST85LP1004A-M-C-LBTE Datasheet

no-image

SST85LP1004A-M-C-LBTE

Manufacturer Part Number
SST85LP1004A-M-C-LBTE
Description
Flash 4GB NANDrive 3.3V
Manufacturer
Greenliant
Datasheet

Specifications of SST85LP1004A-M-C-LBTE

Product Category
Flash
Rohs
yes
Memory Type
NAND Flash
Memory Size
4 GB
Supply Voltage - Max
5 V
Supply Voltage - Min
3.3 V
Maximum Operating Current
115 mA
Operating Temperature
+ 70 C
Mounting Style
SMD/SMT
Package / Case
LBGA-88

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SST85LP1004A-M-C-LBTE
Manufacturer:
SST
Quantity:
20 000
©2010 Greenliant Systems, Ltd.
Features
• Industry Standard ATA/IDE Bus Interface
• Low Power, 3.3V Power Supply
• Low Current Operation:
• Power Management Unit
• Expanded Data Protection
• 20-byte Unique ID for Enhanced Security
• Integrated Voltage Detector
– Host Interface: 16-bit access
– Supports up to PIO Mode-6
– Supports up to Multi-word DMA Mode-4
– Supports up to Ultra DMA Mode-6
– Active mode: 115 mA typical
– Sleep mode: 700 µA typical
– Immediate disabling of unused circuitry without host
– Zero wake-up latency
– WP#/PD# pin configurable by firmware for
– Data security through user-selectable protection zones with
– Factory Pre-programmed 10-byte Unique ID
– User-Programmable 10-byte ID
– Prevents inadvertent Write operations due to unex-
intervention
prevention of data overwrites
advanced NAND management technology
pected power-down or brownout.
The GLS85LP1004B NANDrive™ solid-state drive (SSD) combines a NAND controller and
4 GBytes of NAND flash in a multi-chip package. It provides complete ATA/IDE hard disk
drive functionality in a small package for easy, space-saving mounting to a system mother-
board. This makes the GLS85LP1004B NANDrive SSD the ideal data storage solution for
mobile and embedded electronic products that require smaller and more reliable storage.
www.greenliant.com
4 GByte NANDrive
• Pre-programmed Embedded Firmware
• Robust Built-in ECC
• Multi-tasking Technology Enables Fast
• Fast Sustained Read Performance
• Commercial Temperature Range
• 91-ball LBGA package
• All non-Pb (lead-free) Devices are RoHS Compliant
GLS85LP1004B
Sustained Write Performance
– Executes industry standard ATA/IDE commands
– Implements advanced wear-leveling algorithms to sub-
– Embedded Flash File System
– Corrects up to 24 random bits of error
– Up to 7 MByte/sec
– Up to 28 MByte/sec
– 0°C to 70°C
– 14mm x 24mm x 1.3mm
stantially increase the longevity of flash media
S71420-02-000
Advance Information
05/10

Related parts for SST85LP1004A-M-C-LBTE

SST85LP1004A-M-C-LBTE Summary of contents

Page 1

... Factory Pre-programmed 10-byte Unique ID – User-Programmable 10-byte ID • Integrated Voltage Detector – Prevents inadvertent Write operations due to unex- pected power-down or brownout. ©2010 Greenliant Systems, Ltd. 4 GByte NANDrive GLS85LP1004B • Pre-programmed Embedded Firmware – Executes industry standard ATA/IDE commands – Implements advanced wear-leveling algorithms to sub- stantially increase the longevity of flash media – ...

Page 2

... PDAs, handy terminals, personal communicators, robotics, audio recorders, monitoring devices, and set-top boxes. Greenliant NANDrive is a solid state drive designed for embedded ATA/IDE protocol systems and supports standard ATA/IDE protocol with up to PIO Mode-6, Multi-word DMA Mode-4 and Ultra DMA Mode-6 interface. The built in microcontroller and file management firmware communicates with ATA standard interfaces ...

Page 3

... SCI interface in the PCB design to aid in design validation. Multi-tasking Interface The multi-tasking interface enables fast, sustained write performance by allowing concurrent Read, Program, and Erase operations to multiple flash media devices. ©2010 Greenliant Systems, Ltd. 3 Advance Information S71420-02-000 05/10 ...

Page 4

... The product also supports a global wear-leveling feature which can be enabled or disabled by the Host command. When the global wear-leveling is enabled, the wear-leveling is performed both across and within the groups. Please contact Greenliant for more information about this feature. By default, global wear-leveling is enabled. ...

Page 5

... GByte NANDrive GLS85LP1004B Functional Blocks Embedded File System SRAM Buffer HOST ATA/IDE BUS Figure 1: NANDrive Block Diagram ©2010 Greenliant Systems, Ltd. NAND Controller MCU Flash ECC Internal DMA PMU SCI 5 Advance Information NANDrive NAND Flash 1420 B1.0 S71420-02-000 05/10 ...

Page 6

... DNU 9 DNU DNU DNU 1 DNU DNU Figure 2: Pin Assignments for 91-Ball LBGA ©2010 Greenliant Systems, Ltd. TOP VIEW (balls facing down) DASP# V D11 D14 IOWR# V PDIAG# CSEL DD SS SCID D9 D10 D13 D15 IOCS16# A2 CS3FX# DNU OUT SCID ...

Page 7

... L3 I CS3FX# L8 CSEL L9 I IORD ©2010 Greenliant Systems, Ltd. I/O Type Name and Functions I1Z A[2:0] are used to select one of eight registers in the Task File. I1Z/O2 D[15:0] Data bus I2U DMA Acknowledge - input from host O2 DMA Request to host CS1FX# is the chip select for the task file registers ...

Page 8

... V E2, E9, K5, DD PWR L5, M2, M9 ©2010 Greenliant Systems, Ltd. I/O Type Name and Functions IOWR#: This is an I/O Write Strobe generated by the host. When Ultra DMA mode is not active, this signal is used to clock I/O data into the device. (This pin supports two functions) I2Z ...

Page 9

... B10,D2, D3, D4, D5, D6, E5,E6, F5, G5, J7, L4, L6, L7, M3, M4, M5, M6, M7, M8, N2, N3, N4, N5, N6, N7, N8, N9, R1, R2, R9, R10, T1, T2, T9, T10 1. Any VSS or VDD pin must not be left open or floating. ©2010 Greenliant Systems, Ltd. I/O Type Name and Functions Do not use. 9 Advance Information T1.4 1420 S71420-02-000 05/10 ...

Page 10

... NANDrive to reject any destructive commands from the ATA interface. All destructive commands will return 51H in the Status register and 04H in the Error register signifying an invalid command. All non-destructive commands will be executed normally. ©2010 Greenliant Systems, Ltd. Cylinders Heads 7086 ...

Page 11

... ATA/IDE Host Interface The ATA/IDE host interface can be used for NANDrive manufacturing support. Greenliant provides an example of a DOS- and Windows™-based solution (an executable routine) for manufacturing debug and rework. ...

Page 12

... Task File Read Data Register Write Data Register Read Control Register Write Alt Status Read 1. If 8-bit data transfer mode is enabled. In 8-bit data transfer mode, High Byte is undefined for Data Out. For Data In, X can be V ©2010 Greenliant Systems, Ltd 90% Symbol T R ...

Page 13

... Flush-Cache Flush-Cache-EXT Identify-Drive Idle Idle-Immediate Initialize-Drive-Parameters NOP Read-Buffer Read-DMA Read-DMA-EXT Read-Multiple Read-Multiple-EXT Read-Sector(s) Read-Sector(s)-EXT Read-Verify-Sector(s) Read-Verify-Sector(s)-EXT Recalibrate Security-Disable-Password Security-Erase-Prepare Security-Erase-Unit Security-Freeze-Lock Security-Set-Password Security-Unlock Seek Set-Features SMART Set-Multiple-Mode ©2010 Greenliant Systems, Ltd. 1,2 2,3 2,4 Code E5H or 98H - - - 90H - - - E7H - - - EAH - - - ECH - - ...

Page 14

... Drive. This command has the same protocol as the Read-Sector(s) command. The parameter words in the buffer have the arrangement and meanings defined in Table 8. All reserved bits or words are zero. Table 8 gives the definition for each field in the Identify-Drive information. ©2010 Greenliant Systems, Ltd. 1,2 2,3 ...

Page 15

... Reserved 2 Default number of sectors per track 4 Number of sectors per device (Word 7 = MSW, Word 8 = LSW) 2 Vendor Unique 10 User-programmable serial number in ASCII 10 Greenliant preset, unique ID in ASCII 2 Retired 2 Vendor Unique 2 Vendor Unique 8 Firmware revision in ASCII. Big Endian Byte Order in Word 40 User Definable Model number ...

Page 16

... LBA translation mode. This field is only required by CF feature set support. Word 10-19: Serial Number The contents of this field are right justified and padded with spaces (20H). The right-most ten bytes are a Greenliant preset, unique ID. The left-most ten bytes are a user-programmable value with a default value of “0000000000”. ©2010 Greenliant Systems, Ltd. ...

Page 17

... Even Byte is always valid. The Even Byte value depends on the value set by the Set Multiple command. The Even Byte of this word by default contains a 00H which indicates that Read/Write Multiple commands are not valid. ©2010 Greenliant Systems, Ltd. 17 Advance Information S71420-02-000 ...

Page 18

... DMA transfers on a per word basis. NANDrive supports up to Multi-word DMA Mode-2, so this field is set to 120ns. Note: NANDrive is capable of supporting Multi-word DMA Mode-4 cycle time of 80ns (0050H). Contact Greenliant sales for more details. Word 66: Device Recommended Multi-word DMA Cycle Time This field defines the NANDrive recommended Multi-word DMA transfer cycle time. This field ...

Page 19

... NANDrive supports Multi-word DMA Mode-2, so this field is set to 120ns. Note: NANDrive is capable of supporting Multi-word DMA Mode-4 cycle time of 80ns (0050H). Contact Greenliant sales for more details. Word 67: Minimum PIO Transfer Cycle Time Without Flow Control This field defines, in nanoseconds, the minimum cycle time that, if used by the host, the device guarantees data integrity during the transfer without utilization of IORDY flow control ...

Page 20

... The values in this word should not be depended on by host implementers. Bit Function 15 0: Provides indication that the features/command sets supported words are valid 14 1: Provides indication that the features/command sets supported words are valid 13-0 0: Reserved ©2010 Greenliant Systems, Ltd. 4 GByte NANDrive 20 GLS85LP1004B S71420-02-000 05/10 ...

Page 21

... Address feature set supported 9 0: Reserved 8 1: Set-Max security extension supported 7-5 0: Reserved 4 0: Removable Media Status feature set is not enabled 3 0: Advanced Power Management feature set is not enabled 2 0: CFA feature set is disabled ©2010 Greenliant Systems, Ltd. sets enabled 21 Advance Information S71420-02-000 05/10 ...

Page 22

... Ultra DMA mode 0 is supported Word 89: Time required for Security Word 89 specifies the time required for the Security Erase Unit command to complete. Value Time 0 Value not specified 1-254 (Value * 2) minutes 255 >508 minutes ©2010 Greenliant Systems, Ltd. 4 GByte NANDrive erase unit completion 22 GLS85LP1004B S71420-02-000 05/10 ...

Page 23

... Greenliant Systems, Ltd. hanced security erase unit completion Reserved. 0: Device 1 did not assert PDIAG-. 1: Device 1 asserted PDIAG-. These bits indicate how Device 1 determined the device number: 00: Reserved. 01: A jumper was used. 10: The CSEL signal was used. ...

Page 24

... NANDrive does not support security mode feature set Word 217: Nominal Media Rotation Word 217 indicates the nominal media rotation rate of the device. For NANDrive, the value is always 0001H for this field to indicate non-rotating media. ©2010 Greenliant Systems, Ltd. 4 GByte NANDrive Rate 24 ...

Page 25

... Enable Power-on Reset (POR) establishment of defaults at software reset. Features 01H and 81H are used to enable and clear 8-bit data transfer mode. If the 01H feature command is issued all data transfers will occur on the low order D signal will not be asserted for data register accesses. ©2010 Greenliant Systems, Ltd ...

Page 26

... Power-down mode is enabled. If the sector count is zero, the auto- matic Power-down mode is also enabled, the timer count is set to 3, with each count being 5 ms. Note that this time base (5 msec) is different from the ATA specification. ©2010 Greenliant Systems, Ltd. Bits [7:3] 00000b ...

Page 27

... Once the mode is set with this command, the device will stay in the configured mode until the next time this command is issued. Power-off or reset will not change the configured mode. ©2010 Greenliant Systems, Ltd ...

Page 28

... Read-Verify-Sector(s)-EXT Recalibrate Security-Disable-Password Security-Erase-Prepare Security-Erase-Unit Security-Freeze-Lock Security-Set-Password Security-Unlock Seek Set-Features Set-Multiple-Mode Set-Sleep-Mode Set-WP#/PD#-Mode SMART Standby Standby-Immediate Write-Buffer Write-DMA Write-DMA-EXT Write-Multiple ©2010 Greenliant Systems, Ltd Error Register ICRC/ BBK UNC IDNF ABRT AMNF ...

Page 29

... Write-Sector(s) Write-Sector(s)-EXT Write-Verify Invalid-Command-Code 1. The host is required to reissue any media access command (such as Read-Sector and Write Sector) that ends with an error condition. 2. See Table valid on this command. ©2010 Greenliant Systems, Ltd. 1 (Continued Error Register ICRC/ BBK UNC IDNF ...

Page 30

... PU-WRITE1 1. This parameter is measured only for initial qualification and after a design or process change that could affect this parameter. ©2010 Greenliant Systems, Ltd. 1 I1, I2, O2, O3, and O4 to Ground Potential . . . . . . . . . -2. 25°C 1.0W A ...

Page 31

... This parameter is measured only for initial qualification and after a design or process change that could affect this parameter. Table 17: Reliability Characteristics Symbol Parameter 1 I Latch Up LTH 1. This parameter is measured only for initial qualification and after a design or process change that could affect this parameter. ©2010 Greenliant Systems, Ltd. Test Condition I Minimum Specification Units 100 + I ...

Page 32

... GLS85LP1004B DD I PWR GLS85LP1004B SP 1. Sequential data transfer from host interface and write data to media. 2. This parameter is measured only for initial qualification and after a design or process change that could affect this parameter. ©2010 Greenliant Systems, Ltd. Min Max 2 -10 20 120 -120 1.75 1 ...

Page 33

... Input rise and fall times (10% DD Figure 4: AC Input/Output Reference Waveforms Appendix Differences Between the Greenliant NANDrive and ATA Specifications Idle Timer The Idle timer uses an incremental value of 5 ms, rather than the 5 sec minimum increment value specified in ATA specifications. Recovery from Sleep Mode For NANDrive devices, recovery from sleep mode is accomplished by simply issuing another com- mand to the device ...

Page 34

... C = Commercial: 0°C to +70°C NAND Type M = MLC Version Version Capacity 004 = 4 GByte MByte or GByte Designator 1 = GByte Interface P= Parallel ATA/IDE Interface Voltage L = 3.3V Product Series 85 = NANDrive 1. Environmental suffix “E” denotes non-Pb sol- der. Greenliant non-Pb solder devices are “RoHS Compliant”. S71420-02-000 05/10 ...

Page 35

... A1 CORNER 9 0.40 ±0.05 SEATING PLANE Figure 5: NANDrive 91-Ball, Low-profile Ball Grid Array (LBGA) Greenliant Package Code: LFT ©2010 Greenliant Systems, Ltd. TOP VIEW 24.0 ±0.1 BOTTOM VIEW 15.0 9.0 1.0 7.0 1 ...

Page 36

... Refer to www.greenliant.com for the most recent data sheet versions. Memory sizes denote raw storage capacity; actual usable capacity may be less. Greenliant makes no warranty for the use of its products other than those expressly contained in the Standard Terms and Conditions of Sale which are available on www.greenliant.com. ...