Datasheet
Figure 32. Serializer State Diagram, CDS = High (Camera Application)
Figure 33. Deserializer State Diagram, CDS = High (Camera Application)
Note: The explanation of HDCP operation in this data
sheet is given as a guide for general understanding.
Implementation of HDCP in a product must meet the
requirements given in the HDCP System v1.3 Amendment
for GMSL available from DCP, LLC.
ALL STATES
SLEEP = 1
AUTOS PIN
Content Protection (HDCP)
PWDN = LOW OR
SETTING
HIGH
LOW
POWER-OFF
ALL STATES
SLEEP
NO SIGNAL
DETECTED
High-Bandwidth Digital
SEREN
1
0
POWER-UP VALUE
WAKE-UP SIGNAL
POWER-DOWN
REVERSE LINK
PWDN = HIGH,
AUTOS = HIGH
POWER-OFF
POWER-ON,
PWDN = LOW OR
FOR > 8ms
SLEEP = 1
POWER-OFF
OR
POWER-ON
(REVERSE
CHANNEL
ACTIVE)
IDLE
SLEEP
0
1
PWDN = HIGH,
AUTOS = LOW
POWER-ON
SLEEP = 0,
WAKE-UP
SLEEP = 1
HDCP Gigabit Multimedia Serial
PWDN = HIGH,
POWER-DOWN
POWER-ON
POWER-OFF
DETECTED
SIGNAL
OR
PCLKIN RUNNING
LINK LOCKING
SEREN = 1,
SLEEP = 0,
SEREN = 0
VIDEO
Link Serializer/Deserializer
VIDEO LINK
SERIAL PORT
LOCKED
LOCKING
SEREN = 0 OR
NO PCLKIN
VIDEO LINK
VIDEO LINK
UNLOCKED
LOCKED
POWER-ON
HDCP uses two main phases of operation: authentication
and the link integrity check. The FC starts authentica-
tion by writing to the START_AUTHENTICATION bit in
the serializer. The serializer generates a 64-bit random
number. The host FC first reads the 64-bit random num-
ber from the serializer and writes it to the deserializer.
The FC then reads the serializer public key selection
vector (AKSV) and writes it to the deserializer. The FC
IDLE
VIDEO LINK
UNLOCKED
VIDEO LINK
OPERATING
CONFIG LINK
CONFIG LINK
UNLOCKED
LOCKED
CLINKEN = 0 OR
CLINKEN = 1
SEREN = 1
VIDEO LINK
OPERATING
SEREN = 0 OR
NO PCLKIN
LINK OPERATING
PRBSEN = 0
PRBSEN = 1
REGISTERS
PROGRAM
CONFIG
CLINKEN = 0 OR
LINK STARTED
SEREN = 1
PRBSEN = 0
PRBSEN = 1
CONFIG
VIDEO LINK
PRBS TEST
CONFIG LINK
CONFIG LINK
UNLOCKED
VIDEO LINK
PRBS TEST
LOCKED
CONFIG LINK
OPERATING
REGISTERS
PROGRAM
45

Related parts for MAX9263GCB/V+T