MAX9217ECM Maxim Integrated, MAX9217ECM Datasheet - Page 10

no-image

MAX9217ECM

Manufacturer Part Number
MAX9217ECM
Description
Serializers & Deserializers - Serdes 27-Bit DC-Balanced Serializer
Manufacturer
Maxim Integrated
Type
Serializerr
Datasheet

Specifications of MAX9217ECM

Data Rate
700 Mbit/s
Input Type
LVCMOS/LVTTL
Output Type
LVDS
Number Of Inputs
27
Number Of Outputs
1
Operating Supply Voltage
3 V to 3.6 V
Operating Temperature Range
- 40 C to + 85 C
Package / Case
TQFP-48
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Mounting Style
SMD/SMT

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MAX9217ECM
Manufacturer:
MAXIM
Quantity:
5
Part Number:
MAX9217ECM
Manufacturer:
MAXIM/美信
Quantity:
20 000
Part Number:
MAX9217ECM+
Manufacturer:
NSC
Quantity:
6 150
Part Number:
MAX9217ECM+
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
MAX9217ECM+
Manufacturer:
MAXIM/美信
Quantity:
20 000
Part Number:
MAX9217ECM+T
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
MAX9217ECM+T
Manufacturer:
MAXIM/美信
Quantity:
20 000
Part Number:
MAX9217ECM/V+
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
MAX9217ECM/V+
Manufacturer:
MAXIM/美信
Quantity:
20 000
Part Number:
MAX9217ECM/V+T
Manufacturer:
Maxim Integrated
Quantity:
10 000
27-Bit, 3MHz-to-35MHz
DC-Balanced LVDS Serializer
The transition words require interconnect bandwidth
and displace control data. Therefore, control data is not
sampled (see Figure 9):
• Two clock cycles before DE_IN goes high.
• During the video phase.
• Two clock cycles after DE_IN goes low.
The last sampled control data are latched at the deserial-
izer control data outputs during the transition and video
phases. Video data are latched at the deserializer RGB
data outputs during the transition and control phases.
AC-coupling increases the common-mode voltage to
the voltage rating of the capacitor. Two capacitors are
sufficient for isolation, but four capacitors—two at the
serializer output and two at the deserializer input—pro-
vide protection if either end of the cable is shorted to a
high voltage. AC-coupling blocks low-frequency
ground shifts and common-mode noise. The MAX9217
serializer can also be DC-coupled to the MAX9218
deserializer.
Figure 9. Transition Timing
10
CNTL_IN
PCLK_IN
RGB_IN
______________________________________________________________________________________
DE_IN
CONTROL
PHASE
= NOT SAMPLED BY PCLK_IN
Applications Information
AC-Coupling Benefits
TRANSITION
PHASE
Transition Timing
VIDEO PHASE
Figure 10 shows an AC-coupled serializer and deserial-
izer with two capacitors per link, and Figure 11 is the
AC-coupled serializer and deserializer with four capaci-
tors per link.
See Figure 12 for calculating the capacitor values for
AC-coupling, depending on the parallel clock frequen-
cy. The plot shows capacitor values for two- and four-
capacitor-per-link systems. For applications using less
than 18MHz clock frequency, use 0.1µF capacitors.
The RNG[1:0] inputs select the operating frequency
range of the MAX9217 serializer. An external clock with-
in this range is required for operation. Table 3 shows
the selectable frequency ranges and corresponding
data rates for the MAX9217.
Selection of AC-Coupling Capacitors
Frequency-Range Setting RNG[1:0]
TRANSITION
PHASE
CONTROL
PHASE