Page 1
... FAULT Indicator Output ♦ ♦ 0.09Ω (typ) On-Resistance Applications PART MAX890LC/D MAX890LESA+ MAX890LESA/ order this unit in tape and reel, add (T) to the end of the part number. ** Dice are tested Denotes a lead(Pb)-free/RoHS-compliant package. /V denotes an automotive qualified part. TOP VIEW OUTPUT 0.1μ ...
Page 2
Current-Limited, High-Side P-Channel Switch with Thermal Shutdown ABSOLUTE MAXIMUM RATINGS IN to GND ................................................................-0.3V to +6V ON, FAULT to GND .................................................-0.3V to +6V SET, OUT to GND ...................................... -0. Maximum Continuous Switch Current ..................................1.5A Continuous Power Dissipation ...
Page 3
P-Channel Switch with Thermal Shutdown ELECTRICAL CHARACTERISTICS (V = +3V -40°C to +85°C, unless otherwise noted.) (Note PARAMETER Operating Voltage Quiescent Current Off-Supply Current Off-Switch Current Undervoltage Lockout On-Resistance Current-Limit-Amplifier Threshold Current ...
Page 4
Current-Limited, High-Side P-Channel Switch with Thermal Shutdown __________________________________________Typical Operating Characteristics (T = +25°C, unless otherwise noted.) A QUIESCENT CURRENT vs. INPUT VOLTAGE GND OUT ...
Page 5
P-Channel Switch with Thermal Shutdown ____________________________Typical Operating Characteristics (continued +25°C, unless otherwise noted.) A OUTPUT OVERLOAD (SLOW LOOP RESPONSE 0V, 0A 2μs/div C = 100μ 0.1μF IN OUT 1V/div, AC-COUPLED ...
Page 6
... Fault-Indicator Output. This open-drain output goes low when in current limit or when the die temperature FAULT 8 exceeds +135°C. Detailed Description The MAX890L P-channel MOSFET power switch limits output current to a programmed level. When the output current is increased beyond the programmed current limit the current also increases through ...
Page 7
P-Channel Switch with Thermal Shutdown MAX890L SET GND Figure 2. Setting the Current Limit Thermal Shutdown The MAX890L features thermal shutdown. The switch turns off when the junction temperature exceeds +135°C. Once the device cools by 10°C, the switch turns ...
Page 8
... P-Channel Switch with Thermal Shutdown REVISION REVISION NUMBER DATE Added the MAX890LESA/V+ part number to the Ordering Information, deleted the Chip 4 4/11 Information section Maxim cannot assume responsibility for use of any circuitry other than circuitry entirely embodied in a Maxim product. No circuit patent licenses are implied ...