MAX1940EEE Maxim Integrated, MAX1940EEE Datasheet - Page 7

no-image

MAX1940EEE

Manufacturer Part Number
MAX1940EEE
Description
Power Switch ICs - USB Triple USB Switch w/Autoreset
Manufacturer
Maxim Integrated
Datasheet

Specifications of MAX1940EEE

Supply Voltage - Min
4 V
Supply Voltage - Max
5.5 V
Number Of Switches
Triple
Supply Current
0.9 A

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MAX1940EEE
Manufacturer:
MAXIM
Quantity:
5
Part Number:
MAX1940EEE
Manufacturer:
MAXIM/美信
Quantity:
20 000
PIN
10
11
12
13
14
15
16
1
2
3
4
5
6
7
8
9
FAULTC
FAULTB
FAULTA
NAME
OUTC
OUTB
OUTA
ONC
GND
ONA
ONB
SEL
IN1
IN2
IN3
IN4
IN5
_______________________________________________________________________________________
Control Input for Switch A. The active polarity of ONA is set by SEL (see Table 1).
Power Input. Connect all IN_ inputs together and bypass with a 0.1µF ceramic capacitor to GND. Load
conditions might require additional bulk capacitance to prevent pulling IN_ down.
Power Input. Connect all IN_ inputs together and bypass with a 0.1µF ceramic capacitor to GND. Load
conditions might require additional bulk capacitance to prevent pulling IN_ down.
Power Input. Connect all IN_ inputs together and bypass with a 0.1µF ceramic capacitor to GND. Load
conditions might require additional bulk capacitance to prevent pulling IN_ down.
Control Input for Switch B. The active polarity of ONB is set by SEL (see Table 1).
Power Input. Connect all IN_ inputs together and bypass with a 0.1µF ceramic capacitor to GND. Load
conditions might require additional bulk capacitance to prevent pulling IN_ down.
Power Input. Connect all IN_ inputs together and bypass with a 0.1µF ceramic capacitor to GND. Load
conditions might require additional bulk capacitance to prevent pulling IN_ down.
Control Input for Switch C. The active polarity of ONC is set by SEL (see Table 1).
Fault Indicator Output for Switch C. Open-drain output asserts low when switch C enters thermal shutdown,
undervoltage lockout, or a sustained (>20ms) current-limit or short-circuit condition.
Power Output for Switch C. Bypass OUTC to GND with a 1µF ceramic capacitor. Load conditions might
require additional bulk capacitance. When disabled, OUTC goes into a high-impedance state.
Logic Input Polarity Select. SEL sets the active polarity of the ON_ inputs. Connect SEL high to set active-
high inputs. Connect SEL to GND to set active-low inputs.
Fault Indicator Output for Switch B. Open-drain output asserts low when switch B enters thermal shutdown,
undervoltage lockout, or enters a sustained (>20ms) current-limit or short-circuit condition.
Power Output for Switch B. Bypass OUTB to GND with a 1µF ceramic capacitor. Load conditions might
require additional bulk capacitance. When disabled, OUTB goes into a high-impedance state.
Ground
Power Output for Switch A. Bypass OUTA to GND with a 1µF ceramic capacitor. Load conditions might
require additional bulk capacitance. When disabled, OUTA goes into a high-impedance state.
Fault Indicator Output for Switch A. Open-drain output asserts low when switch A enters thermal shutdown,
undervoltage lockout, or a sustained (>20ms) current-limit or short-circuit condition.
Triple USB Switch with Autoreset and
FUNCTION
Fault Blanking
Pin Description
7