MAX16047ATN+T Maxim Integrated, MAX16047ATN+T Datasheet - Page 14

no-image

MAX16047ATN+T

Manufacturer Part Number
MAX16047ATN+T
Description
Supervisory Circuits 12Ch EEPROM Prob System Manager
Manufacturer
Maxim Integrated
Series
MAX16047, MAX16049r
Datasheet

Specifications of MAX16047ATN+T

Rohs
yes
12-Channel/8-Channel EEPROM-Programmable
System Managers with Nonvolatile Fault Registers
Note: This data sheet uses a specific convention for referring to bits within a particular address location. As an example, r0Fh[3:0]
refers to bit 3 through 0 in register with address 15 decimal.
14
Extended
Default and
EEPROM
EEPROM
PAGE
______________________________________________________________________________________
Software Enable and Margin
(Registers r50h to r5Bh and
RESET and Fault Outputs
User EEPROM (Registers
Undervoltage Thresholds
ADC Conversion Results
(Registers r1Ah to r1Bh)
(Registers r1Ch to r1Eh)
(Registers r47h to r4Ch)
(Registers r15h to r1Bh)
(Registers r00h to r17h)
(Registers r18h to r19h)
(Registers r0Fh to r11h)
(Registers r23h to r46h)
(Registers r1Fh to r22h)
Watchdog Functionality
(Registers r00h to r0Eh)
ADC Range Selections
Programmable Output
GPIO Configuration
Sequencing-Mode
Fault Log Results
Failed Line Flags
Overvoltage and
(Register r4Dh)
(Register r55h)
Fault Behavior
Configuration
Configuration
r9Ch to rFFh)
r5Eh to r63h)
REGISTER
GPIO Data
Input ADC conversion results. ADC writes directly to these registers during normal
operation. ADC input ranges (MON1–MON12) are selected with registers r0Fh to r11h.
Voltage fault flag bits. Flags for each input signal when undervoltage or overvoltage
threshold is exceeded.
GPIO state data. Used to read back and control the state of each GPIO.
ADC input voltage range. Selects the voltage range of the monitored inputs.
Selects how the device should operate during faults. Options include latch-off or
autoretry after fault. The autoretry delay is selectable (r4Fh). Use registers r48h
through r4Ch to select fault conditions that trigger a critical fault event.
General-purpose input/output configuration registers. GPIOs are configurable as a
manual-reset input, a margin disable input, a watchdog timer input and output, logic
inputs/outputs, fault-dependent outputs, or as the feedback/pulldown inputs (INS_) for
closed-loop tracking.
Input overvoltage and undervoltage thresholds. ADC conversion results are compared
to overvoltage and undervoltage threshold values stored here. MON_ voltages
exceeding threshold values trigger a fault event.
Programmable output configurations. Selectable output configurations include: active-
low or active-high, open-drain or push-pull outputs. EN_OUT1–EN_OUT6 are
configurable as charge-pump outputs and EN_OUT1–EN_OUT4 can be configured for
closed-loop tracking.
RESET, FAULT1, and FAULT2 output configuration. Programs the functionality of the
RESET, FAULT1, and FAULT2 outputs, as well as which inputs they depend on.
Assign inputs and outputs for sequencing. Select sequence delays (20µs to 1.6s) with
registers r50h through r54h. Use register r54h to enable/disable the reverse sequence
bit for power-down operation.
Use register r4Dh to set the Software Enable bit, to select early warning thresholds
and undervoltage/overvoltage, to enable/disable margining, and to enable/disable the
watchdog for independent/dependent mode.
Configure watchdog functionality for GPIO5 and GPIO6.
ADC conversion results and failed-line flags at the time of a fault. These values are
recorded by the fault event logger at the time of a critical fault.
User-available EEPROM
Register Summary (All Registers 8-Bits Wide)
DESCRIPTION

Related parts for MAX16047ATN+T