AT25DF161-SSH-B Atmel, AT25DF161-SSH-B Datasheet - Page 23

IC FLASH 16MBIT 100MHZ 8SOIC

AT25DF161-SSH-B

Manufacturer Part Number
AT25DF161-SSH-B
Description
IC FLASH 16MBIT 100MHZ 8SOIC
Manufacturer
Atmel
Datasheet

Specifications of AT25DF161-SSH-B

Format - Memory
FLASH
Memory Type
DataFLASH
Memory Size
16M (2M x 8)
Speed
100MHz
Interface
SPI, RapidS
Voltage - Supply
2.7 V ~ 3.6 V
Operating Temperature
-40°C ~ 85°C
Package / Case
8-SOIC (3.9mm Width)
Density
16Mb
Access Time (max)
5ns
Interface Type
Serial (SPI)
Boot Type
Not Required
Address Bus
1b
Operating Supply Voltage (typ)
3.3V
Operating Temp Range
-40C to 85C
Package Type
SOIC
Program/erase Volt (typ)
2.7 to 3.6V
Sync/async
Synchronous
Operating Temperature Classification
Industrial
Operating Supply Voltage (min)
2.7V
Operating Supply Voltage (max)
3.6V
Word Size
8b
Number Of Words
2M
Supply Current
19mA
Mounting
Surface Mount
Pin Count
8
Mounting Style
SMD/SMT
Memory Configuration
8192 Pages X 256 Bytes
Clock Frequency
100MHz
Supply Voltage Range
2.7V To 3.6V
Memory Case Style
SOIC
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT25DF161-SSH-B
Manufacturer:
ROHM
Quantity:
40 000
3687E–DFLASH–11/10
9.6
logical “1” without affecting the current sector protection status (no changes will be made to the Sector Protection
Registers).
When writing to the first byte of the Status Register, bits five, four, three, and two will not actually be modified but will be
decoded by the device for the purposes of the Global Protect and Global Unprotect functions. Only bit seven, the SPRL bit,
will actually be modified. Therefore, when reading the first byte of the Status Register, bits five, four, three, and two will not
reflect the values written to them but will instead indicate the status of the WP pin and the sector protection status. Please
refer to
values can be read for bits five, four, three, and two.
Read Sector Protection Registers
The Sector Protection Registers can be read to determine the current software protection status of each sector. Reading
the Sector Protection Registers, however, will not determine the status of the WP pin.
To read the Sector Protection Register for a particular sector, the CS pin must first be asserted and the opcode of 3Ch must
be clocked in. Once the opcode has been clocked in, three address bytes designating any address within the sector must
be clocked in. After the last address byte has been clocked in, the device will begin outputting data on the SO pin during
every subsequent clock cycle. The data being output will be a repeating byte of either FFh or 00h to denote the value of
the appropriate Sector Protection Register.
At clock frequencies above f
above f
appropriate Sector Protection Register.
Table 9-3.
Deasserting the CS pin will terminate the read operation and put the SO pin into a high-impedance state. The CS pin can
be deasserted at any time and does not require that a full byte of data be read.
In addition to reading the individual Sector Protection Registers, the Software Protection Status (SWP) bits in the Status
Register can be read to determine if all, some, or none of the sectors are software protected (refer to
Register” on page 30
Figure 9-5.
Output Data
SCK
SO
CS
SI
00h
CLK
FFh
“Read Status Register” on page 30
, at least two bytes of data must be clocked out from the device in order to determine the correct status of the
Read Sector Protection Register – Output Data
Read Sector Protection Register
Sector Protection Register Value
Sector Protection Register value is 0 (sector is unprotected)
Sector Protection Register value is 1 (sector is protected)
for more details).
CLK
, the first byte of data output will not be valid. Therefore, if operating at clock frequencies
and
Table 11-1 on page 30
for details on the Status Register format and what
Atmel AT25DF161
“Read Status
23

Related parts for AT25DF161-SSH-B