30016-RT Parallax, 30016-RT Datasheet - Page 2

no-image

30016-RT

Manufacturer Part Number
30016-RT
Description
Audio IC Development Tools Emic 2 Text-2-Speech Module RETAIL PKG
Manufacturer
Parallax
Datasheet
Connections
Emic 2 interfaces to a host microcontroller or computer system using only four connections (GND, 5V,
SOUT, SIN). Additional connections (SP+, SP-) are available for direct interfacing to an 8Ω speaker. A
1/8” (3.5mm) audio jack provides a single-ended, monaural output for easy connection to headphones,
amplified speakers, or other audio equipment.
Type: I = Input, O = Output, P = Power, G = Ground
Use the following example circuit for connecting the Emic 2 Text-to-Speech Module:
*Note: For audio output, a connection needs to be made to either SP+/SP- or the 1/8" audio jack. Audio
quality may be affected if both outputs are used at the same time.
Copyright © Parallax Inc.
Pin
1
2
3
4
5
6
Pin Name
SOUT
GND
SP+
SIN
SP-
5V
Type
G
O
O
O
P
I
Emic 2 Text-to-Speech Module (#30016)
Function
System ground. Connect to power supply’s ground (GND)
terminal.
System power, 5 VDC input.
Serial output to host. 5 V TTL-level interface, 9600 bps, 8 data
bits, no parity, 1 stop bit, non-inverted.
Serial input from host. 3.3 V to 5 V TTL-level interface, 9600 bps,
8 data bits, no parity, 1 stop bit, non-inverted.
Differential audio amplifier output, bridge-tied load configuration,
negative side. Connect directly to 8 Ω speaker.
Differential audio amplifier output, bridge-tied load configuration,
positive side. Connect directly to 8 Ω speaker.
v1.1 7/2/2012 Page 2 of 12