DS2726EVKIT+ Maxim Integrated, DS2726EVKIT+ Datasheet

no-image

DS2726EVKIT+

Manufacturer Part Number
DS2726EVKIT+
Description
Power Management IC Development Tools
Manufacturer
Maxim Integrated
Series
DS2726r
Datasheet

Specifications of DS2726EVKIT+

Rohs
yes
19-4841; Rev 8/09
CONNECTING THE DS2726 EVALUATION KIT BOARD
Figure 1. CONNECTION DIAGRAM FOR DS2726EVKIT+
V10 to V0 are voltage sense lines for the individual cells. For a 10-cell battery pack connect V10 to the positive
terminal of the pack. V9 will be connected to the positive terminal of the next cell and so on down to the last cell. V0
connects to the negative terminal of the battery pack. These connections are for voltage sense and cell balancing
only. The maximum amount of current they will sink is 200mA during cell balancing. The load current does not flow
through these connections. For a connection diagram of a battery pack with less than 10 cells, see Figure 1.
The BATT+ connection should be connected to the positive terminal of the battery pack. The path from PACK+ to
BATT+ is your charge and discharge current path. High currents will flow through this path therefore a heavy gauge
wire should be used.
BATT- should be connected to the negative terminal of the battery pack. VSS is the return current path for the load.
www.maxim-ic.com
CHARGER/
LOAD
+
-
VSS
PACK+
VCC
SLP
10-Cell Li-Ion Battery Protector
1 of 5
EV Board
DS2726
BATT-
BATT+
V10
V8
V5
V3
V0
V9
V7
V6
V4
V2
V1
DS2726EVKIT+
Evaluation Kit
Battery Pack
10 Cell

Related parts for DS2726EVKIT+

DS2726EVKIT+ Summary of contents

Page 1

... Rev 8/09 www.maxim-ic.com CONNECTING THE DS2726 EVALUATION KIT BOARD Figure 1. CONNECTION DIAGRAM FOR DS2726EVKIT+ + CHARGER/ LOAD - V10 to V0 are voltage sense lines for the individual cells. For a 10-cell battery pack connect V10 to the positive terminal of the pack. V9 will be connected to the positive terminal of the next cell and so on down to the last cell. V0 connects to the negative terminal of the battery pack ...

Page 2

Figure 2. CELL CONNECTION DIAGRAM FOR LESS THAN 10 CELLS 9 Cell V10 = odd V10 = even V10 V10 ...

Page 3

Table 2 CBS0 CBS1 Cell balancing voltage: Example: Cell balancing will begin when a cell’s voltage is greater than 4.1V and will terminate when all cells’ voltages are greater than 4.1V. Number of Cells The number of cells in the ...

Page 4

... V10 GND 26 15 VIN OVS1 28 13 SNS OVS0 CBS1 CBS0 31 10 PKP CBCFG 32 9 Not Populated DS2726EVKIT+ Populated Not Populated Not Populated Not Populated Not Populated Not Populated Not ...

Page 5

... DATE 8/09 Changed the ordering part number from DS2726K to DS2726EVKIT+. Maxim cannot assume responsibility for use of any circuitry other than circuitry entirely embodied in a Maxim product. No circuit patent licenses are implied. Maxim reserves the right to change the circuitry and specifications without notice at any time. ...